Interlaboratory comparison of dicentric chromosome assay using electronically transmitted images
García, O.; Di Giorgio, Marina; Vallerga, María Belén
; Radl, Analía; Taja, María Rosa; Seoane, Analia Isabel
; de Luca, Julio Cesar
; Stuck Oliveira, Mónica; Valdivia, Patricia; Lamadrid, Ana Ilsa; González, Jorge Ernesto; Romero, I.; Mandina, Tania; Pantelias, G.; Terzoudi, G.; Guerrero Carbajal, Citlalo; Arceo Maldonado, Carolina; Espinoza, Marco; Oliveros, Nilda; Martinez Lopez, Wilner; Di Tomasso, Maria Vittoria; Mendez, Leticia Jesica
; Puig, Nora Raquel; Roy, Laurence; Barquinero, J.F.
Fecha de publicación:
04/2013
Editorial:
Oxford University Press
Revista:
Radiation Protection Dosimetry
ISSN:
0144-8420
Idioma:
Inglés
Tipo de recurso:
Artículo publicado
Clasificación temática:
Resumen
The bottleneck in data acquisition during biological dosimetry based on a dicentric assay is the need to score dicentrics in a large number of lymphocytes. One way to increase the capacity of a given laboratory is to use the ability of skilled operators from other laboratories. This can be done using image analysis systems and distributing images all around the world. Two exercises were conducted to test the efficiency of such an approach involving 10 laboratories. During the first exercise (E1), the participant laboratories analysed the same images derived from cells exposed to 0.5 and 3 Gy; 100 images were sent to all participants for both doses. Whatever the dose, only about half of the cells were complete with well-spread metaphases suitable for analysis. A coefficient of variation (CV) on the standard deviation of ̃15 % was obtained for both doses. The trueness was better for 3 Gy (0.6 %) than for 0.5 Gy (37.8 %). The number of estimated doses classified as satisfactory according to the z-score was 3 at 0.5 Gy and 8 at 3 Gy for 10 dose estimations. In the second exercise, an emergency situation was tested, each laboratory was required to score a different set of 50 images in 2 d extracted from 500 downloaded images derived from cells exposed to 0.5 Gy. Then the remaining 450 images had to be scored within a week. Using 50 different images, the CVon the estimated doses (79.2 %) was not as good as in E1, probably associated to a lower number of cells analysed (50 vs. 100) or from the fact that laboratories analysed a different set of images. The trueness for the dose was better after scoring 500 cells (22.5 %) than after 50 cells (26.8 %). For the 10 dose estimations, the number of doses classified as satisfactory according to the z-score was 9, for both 50 and 500 cells. Overall, the results obtained support the feasibility of networking using electronically transmitted images. However, before its implementation some issues should be elucidated, such as the number and resolution of the images to be sent, and the harmonisation of the scoring criteria. Additionally, a global website able to be used for the different regional networks, like Share Points, will be desirable to facilitate worldwide communication.
Palabras clave:
Interlaboratory
,
Dicentric Chromosome Assay
,
Image Analysis Systems