Mostrar el registro sencillo del ítem

dc.contributor.author
Aranda Rascon, Miguel Jesus  
dc.contributor.author
Grosse, Constantino  
dc.contributor.author
López García, José Juan  
dc.contributor.author
Horno, José  
dc.date.available
2019-06-10T19:46:00Z  
dc.date.issued
2009-08  
dc.identifier.citation
Aranda Rascon, Miguel Jesus; Grosse, Constantino; López García, José Juan; Horno, José; Influence of the finite ion size on the predictions of the standard electrokinetic model: Frequency response; Academic Press Inc Elsevier Science; Journal of Colloid and Interface Science; 336; 2; 8-2009; 857-864  
dc.identifier.issn
0021-9797  
dc.identifier.uri
http://hdl.handle.net/11336/77882  
dc.description.abstract
An extension into the frequency domain of our previous static and stationary works that modify the standard electrokinetic model taking into account the finite size of ions in the electrolyte solution [J.J. López-García, M.J. Aranda-Rascón, J. Horno, J. Colloid Interface Sci. 316 (2007) 196; J.J. López-García, M.J. Aranda-Rascón, J. Horno, J. Colloid Interface Sci. 323 (2008) 146; M.J. Aranda-Rascón, C. Grosse, J.J. López-García, J. Horno, J. Colloid Interface Sci., in press] is presented. It is shown that the excluded volume effect can be quite substantial in some cases and is not negligible even for weakly charged particles. Furthermore, it generally improves on the predictions of the standard electrokinetic model since the low-frequency dielectric and conductivity increments as well as the electrophoretic mobility increase with the ion size.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Academic Press Inc Elsevier Science  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
Colloids  
dc.subject
Ion Size  
dc.subject
Permittivity  
dc.subject
Dinamic Mobility  
dc.subject.classification
Astronomía  
dc.subject.classification
Ciencias Físicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Influence of the finite ion size on the predictions of the standard electrokinetic model: Frequency response  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2019-06-10T13:41:46Z  
dc.journal.volume
336  
dc.journal.number
2  
dc.journal.pagination
857-864  
dc.journal.pais
Estados Unidos  
dc.journal.ciudad
New York  
dc.description.fil
Fil: Aranda Rascon, Miguel Jesus. Universidad de Jaén; España  
dc.description.fil
Fil: Grosse, Constantino. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán; Argentina  
dc.description.fil
Fil: López García, José Juan. Universidad de Jaén; España  
dc.description.fil
Fil: Horno, José. Universidad de Jaén; España  
dc.journal.title
Journal of Colloid and Interface Science  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/https://dx.doi.org/10.1016/j.jcis.2009.04.009  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0021979709004536?via%3Dihub