Artículo
Correlation between pore size and reactivity of macro/mesoporous iron and copper hexacyanoferrates for H2O2 electrocatalysis
Gonçales, Vinicius R.; Gaitán, Martin Hernán; Bragatto, Allan de O.P.; Soler Illia, Galo Juan de Avila Arturo
; Baraldo Victorica, Luis Mario
; Córdoba de Torresi, Susana
Fecha de publicación:
08/2013
Editorial:
Elsevier
Revista:
Journal of Electroanalytical Chemistry
ISSN:
0022-0728
Idioma:
Inglés
Tipo de recurso:
Artículo publicado
Clasificación temática:
Resumen
The effect of pore size to H2O2 detection by macroporous and mesoporous Prussian blue type electrocatalysts is reported in the present paper. The macroporous electrocatalysts were prepared employing spherical colloidal particles of different sizes (300, 460, 600 and 800 nm) as sacrificial templates to synthesize a copper hexacyanoferrate/polypyrrole (CuHCNFe/Ppy) hybrid material. Surprisingly, macroporous and non-porous CuHCNFe/Ppy displayed very similar results, which led to a discussion that application of macroporous platforms in sensors must consider the material wettability and the influence of electrochemical kinetics on analyte detection. In order to evaluate the effect of smaller pores, the performance of the macroporous H2O2 sensors was also compared to electrocatalysts synthesized through the immobilization of Prussian blue and CuHCNFe layers inside the cavities of mesoporous TiO2 films with diameters of 13, 20 and 40 nm. In this scale, the results were superior than those achieved with the non-porous sensors, demonstrating the possibility of controlling the performance of H2O2 sensors according to the pore diameter and the amount of immobilized material. Among the tested porous materials, the H2O2 sensor with better performance was achieved using the 20-nm diameter TiO2 platform functionalized with Prussian blue, which presented a sensitivity of (930 ± 50) μA cm-2 mmol-1 L, detection limit of (0.49 ± 0.08) μmol L-1, response time of (6 ± 2) seconds and linear range up to (1.3 ± 0.1) mmol L-1. This performance was extremely satisfactory considering sensors operating by chronoamperometry.
Palabras clave:
Porous Films
,
Pydrogen Peroxide,
,
Prussian Blue,
,
Polypyrrole
Archivos asociados
Licencia
Identificadores
Colecciones
Articulos(INQUIMAE)
Articulos de INST.D/QUIM FIS D/L MATERIALES MEDIOAMB Y ENERGIA
Articulos de INST.D/QUIM FIS D/L MATERIALES MEDIOAMB Y ENERGIA
Articulos(SEDE CENTRAL)
Articulos de SEDE CENTRAL
Articulos de SEDE CENTRAL
Citación
Gonçales, Vinicius R.; Gaitán, Martin Hernán; Bragatto, Allan de O.P.; Soler Illia, Galo Juan de Avila Arturo; Baraldo, Luis M.; et al.;Correlation between pore size and reactivity of macro/mesoporous iron and copper hexacyanoferrates for H2O2 electrocatalysis; Elsevier; Journal of Electroanalytical Chemistry; 706; 8-2013; 48-54
Compartir