Mostrar el registro sencillo del ítem

dc.contributor.author
Kuligowski, J.  
dc.contributor.author
Martínez Galera, M.  
dc.contributor.author
Gil García, M. D.  
dc.contributor.author
Culzoni, Maria Julia  
dc.contributor.author
Goicoechea, Hector Casimiro  
dc.contributor.author
Garrigues, S.  
dc.contributor.author
Quintás, G.  
dc.contributor.author
de la Guardia, Miguel  
dc.date.available
2019-04-16T14:57:16Z  
dc.date.issued
2011-01  
dc.identifier.citation
Kuligowski, J.; Martínez Galera, M.; Gil García, M. D.; Culzoni, Maria Julia; Goicoechea, Hector Casimiro; et al.; Science based calibration for the extraction of 'analyte-specific' HPLC-DAD chromatograms in environmental analysis; Elsevier Science; Talanta; 83; 4; 1-2011; 1158-1165  
dc.identifier.issn
0039-9140  
dc.identifier.uri
http://hdl.handle.net/11336/74459  
dc.description.abstract
Multivariate science based calibration (SBC) has been applied to the resolution of overlapped peaks in liquid chromatography with diode array detection (LC-DAD). Complex river water samples spiked with 11 pharmaceutical substances resulted in poorly resolved chromatograms containing additional peaks from interfering matrix compounds and a change in the background absorbance due to the mobile phase gradient. Applying the present multivariate approach it was possible to resolve all 11 analytes from overlapping peaks, obtaining linear calibration lines (R2 > 0.96). Recovery percentages on spiked samples ranged between 74.6 and 113.5%, which are quite satisfactory taking into account the low concentration ranges considered to 1-7 μg L-1.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Elsevier Science  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
Environmental Analysis  
dc.subject
High Performance Liquid Chromatography-Diode Array Detection (Hplc-Dad)  
dc.subject
Science Based Calibration  
dc.subject.classification
Otras Ciencias Químicas  
dc.subject.classification
Ciencias Químicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Science based calibration for the extraction of 'analyte-specific' HPLC-DAD chromatograms in environmental analysis  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2019-04-05T14:36:01Z  
dc.journal.volume
83  
dc.journal.number
4  
dc.journal.pagination
1158-1165  
dc.journal.pais
Países Bajos  
dc.journal.ciudad
Amsterdam  
dc.description.fil
Fil: Kuligowski, J.. Universidad de Valencia; España  
dc.description.fil
Fil: Martínez Galera, M.. Universidad de Almería; España  
dc.description.fil
Fil: Gil García, M. D.. Universidad de Almería; España  
dc.description.fil
Fil: Culzoni, Maria Julia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; Argentina. Universidad Nacional del Litoral. Facultad de Bioquímica y Ciencias Biológicas; Argentina  
dc.description.fil
Fil: Goicoechea, Hector Casimiro. Universidad Nacional del Litoral. Facultad de Bioquímica y Ciencias Biológicas; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; Argentina  
dc.description.fil
Fil: Garrigues, S.. Universidad de Valencia; España  
dc.description.fil
Fil: Quintás, G.. Universidad de Valencia; España  
dc.description.fil
Fil: de la Guardia, Miguel. Universidad de Valencia; España  
dc.journal.title
Talanta  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://doi.org/10.1016/j.talanta.2010.07.060  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0039914010005904