Rossi, Ezequiel; Errea, María Inés; de Cortalezzi, María Marta Fidalgo; Stripeikis, Jorge Daniel; Selective determination of Cr (VI) by on-line solid phase extraction FI-SPE-FAAS using an ion exchanger resin as sorbent: An improvement treatment of the analytical signal; Elsevier Science; Microchemical Journal; 130; 1-2017; 88-92  
dc.identifier.issn
0026-265X  
dc.identifier.uri
http://hdl.handle.net/11336/72826  
dc.description.abstract
A flow injection (FI) technique based on an on-line solid phase extraction (SPE) coupled with flame atomic absorption spectroscopy (FAAS) to selectively quantify chromium (VI) in the presence of chromium (III) was developed. An anion exchanger was used as solid sorbent and the detection limit found was two order of magnitude lower than that expected quantifying by FAAS. Until now, quantitative determinations in FAAS were carried out by measuring the height of the peaks rather than their area. In our hands, the software was reconfigured and the area under the peaks could be measured. Considering area instead of height, the enhancement factor increases from 6.7 to 360 (approx. 54 times) giving a detection limit of 0.034 μg·L− 1, lower than that obtained using much more expensive instruments such as electrothermal atomic absorption spectrometry (ETAAS) or inductively coupled plasma-atomic emission spectrometry (IPC-AES), greatly enhancing the potential of this methodology for future use in speciation studies. The operation conditions were: pH 3, sample loading 50 mL·min− 1, elution flow rate 7.5 mL·min− 1. The anion exchanger lifetime was over 100 adsorption/desorption cycles. Anions commonly present in natural aqueous systems did not interfere in the chromium retention. The accuracy was validated using a certified reference material (Fluka Analytical, QC3453).  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Elsevier Science  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
Analytical Signal Processing  
dc.subject
Cr (Vi) Selective Analysis  
dc.subject
Flame Atomic Absorption Spectrometry  
dc.subject
Flow Injection  
dc.subject.classification
Otras Ingeniería Química  
dc.subject.classification
Ingeniería Química  
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS  
dc.title
Selective determination of Cr (VI) by on-line solid phase extraction FI-SPE-FAAS using an ion exchanger resin as sorbent: An improvement treatment of the analytical signal  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2019-03-29T12:14:29Z  
dc.journal.volume
130  
dc.journal.pagination
88-92  
dc.journal.pais
Países Bajos  
dc.journal.ciudad
Amsterdam  
dc.description.fil
Fil: Rossi, Ezequiel. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Instituto Tecnológico de Buenos Aires; Argentina  
dc.description.fil
Fil: Errea, María Inés. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Instituto Tecnológico de Buenos Aires; Argentina  
dc.description.fil
Fil: de Cortalezzi, María Marta Fidalgo. University of Missouri; Estados Unidos  
dc.description.fil
Fil: Stripeikis, Jorge Daniel. Instituto Tecnológico de Buenos Aires; Argentina  
dc.journal.title
Microchemical Journal  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S0026265X16302910  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1016/j.microc.2016.08.004