Mostrar el registro sencillo del ítem
dc.contributor.author
Casciaro, Mariano Ezequiel

dc.contributor.author
El Batti, Salma
dc.contributor.author
Chironi, Gilles
dc.contributor.author
Simon, Alain
dc.contributor.author
Mousseaux, Elie
dc.contributor.author
Armentano, Ricardo Luis

dc.contributor.author
Alsac, Jean Marc
dc.contributor.author
Craiem, Damian

dc.date.available
2019-03-29T14:24:26Z
dc.date.issued
2016-05
dc.identifier.citation
Casciaro, Mariano Ezequiel; El Batti, Salma; Chironi, Gilles; Simon, Alain; Mousseaux, Elie; et al.; Deformable Surface Model for the Evaluation of Abdominal Aortic Aneurysms Treated with an Endovascular Sealing System; Springer; Annals Of Biomedical Engineering; 44; 5; 5-2016; 1381-1391
dc.identifier.issn
0090-6964
dc.identifier.uri
http://hdl.handle.net/11336/72807
dc.description.abstract
Rupture of abdominal aortic aneurysms (AAA) is responsible for 1–3% of all deaths among the elderly population in developed countries. A novel endograft proposes an endovascular aneurysm sealing (EVAS) system that isolates the aneurysm wall from blood flow using a polymer-filled endobag that surrounds two balloon-expandable stents. The volume of injected polymer is determined by monitoring the endobag pressure but the final AAA expansion remains unknown. We conceived and developed a fully deformable surface model for the comparison of pre-operative sac lumen size and final endobag size (measured using a follow-up scan) with the volume of injected polymer. Computed tomography images were acquired for eight patients. Aneurysms were manually and automatically segmented twice by the same observer. The injected polymer volume resulted 9% higher than the aneurysm pre-operative lumen size (p < 0.05), and 11% lower than the final follow-up endobag volume (p < 0.01). The automated method required minimal user interaction; it was fast and used a single set of parameters for all subjects. Intra-observer and manual vs. automated variability of measured volumes were 0.35 ± 2.11 and 0.07 ± 3.04 mL, respectively. Deformable surface models were used to quantify AAA size and showed that EVAS system devices tended to expand the sac lumen size.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Springer

dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
Abdominal Aorta
dc.subject
Endograft
dc.subject
Endovascular Repair
dc.subject
Geometrical Deformed Model
dc.subject
Nellix Device
dc.subject.classification
Ciencias Biomédicas Sociales

dc.subject.classification
Ciencias de la Salud

dc.subject.classification
CIENCIAS MÉDICAS Y DE LA SALUD

dc.title
Deformable Surface Model for the Evaluation of Abdominal Aortic Aneurysms Treated with an Endovascular Sealing System
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2019-03-29T12:28:32Z
dc.journal.volume
44
dc.journal.number
5
dc.journal.pagination
1381-1391
dc.journal.pais
Alemania

dc.journal.ciudad
Berlin
dc.description.fil
Fil: Casciaro, Mariano Ezequiel. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Favaloro; Argentina
dc.description.fil
Fil: El Batti, Salma. Service de Chirurgie Cardiaque et Vasculaire; Francia. Université Paris-Descartes; Francia. Universite de Paris V; Francia
dc.description.fil
Fil: Chironi, Gilles. Hôpital Européen Georges Pompidou; Francia. Inserm; Francia. Université Paris-Descartes; Francia
dc.description.fil
Fil: Simon, Alain. Hôpital Européen Georges Pompidou; Francia. Inserm; Francia. Université Paris-Descartes; Francia
dc.description.fil
Fil: Mousseaux, Elie. Inserm; Francia. Université Paris-Descartes; Francia. Service d’Imagerie Cardiovasculaire; Francia
dc.description.fil
Fil: Armentano, Ricardo Luis. Universidad Favaloro; Argentina
dc.description.fil
Fil: Alsac, Jean Marc. Inserm; Francia. Service d’Imagerie Cardiovasculaire; Francia. Université Paris-Descartes; Francia
dc.description.fil
Fil: Craiem, Damian. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Favaloro; Argentina. Hôpital Européen Georges Pompidou; Francia
dc.journal.title
Annals Of Biomedical Engineering

dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://link.springer.com/article/10.1007/s10439-015-1446-9
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/https://dx.doi.org/10.1007/s10439-015-1446-9
Archivos asociados