Mostrar el registro sencillo del ítem
dc.contributor.author
Frisoli, Melisa Antonella
dc.contributor.author
Edelhoff, J. M.
dc.contributor.author
Gersdorff, N.
dc.contributor.author
Nicolet, Jonathan José Carlos
dc.contributor.author
Braidot, Ariel Andrés Antonio
dc.contributor.author
Engelke, W.
dc.date.available
2019-03-21T20:06:47Z
dc.date.issued
2017-01
dc.identifier.citation
Frisoli, Melisa Antonella; Edelhoff, J. M.; Gersdorff, N.; Nicolet, Jonathan José Carlos; Braidot, Ariel Andrés Antonio; et al.; Comparative study using video analysis and an ultrasonic measurement system to quantify mandibular movement; Taylor & Francis; The Journal of Craniomandibular Practice; 35; 1; 1-2017; 19-29
dc.identifier.issn
0886-9634
dc.identifier.uri
http://hdl.handle.net/11336/72229
dc.description.abstract
Objectives: This study provides a direct comparison between two registration systems used in quantifying mandibular opening movements: two-dimensional videography and electronic axiography, which is used as a reference. Method: A total of 32 volunteers (age: 27.2 ± 6.8–gender: 17 F–15 M) participated in the study and repeated a characteristic movement, the frontal Posselt, used in the clinical evaluation of the temporomandibular joint. Results: Frontal Posselt diagrams were reconstructed with the data gathered from both systems, which yielded acceptably similar data. Three commonly assessed parameters were obtained from each diagram and compared. These parameters were: maximum opening, right laterotrusion and left laterotrusion. Both descriptive statistics and the ANOVA test suggested that there was no significant difference between the estimated maximum opening parameter and the reference system (p = 0.217, 95% confidence). Laterotrusion values, on the other hand, appear to be overestimated by videography system and to show greater variability. Discussion: Two-dimensional videography appears to be a suitable tool with resolution that is adequate for tracing mandibular movements–and opening values, in particular–for screening purposes, long-term observation, and as a quick check for dysfunction as far as frontal plane trajectories are concerned. Conclusion: Reliability and acceptable quality of 2D videography data, acquired in this work, show that it has clear advantages for its wide application in the dental office due to simplicity and low cost for maximum opening measurement given the usefulness of this parameter in the detection of temporomandibular disorders.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Taylor & Francis
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
2d Videography
dc.subject
Jaw Movement
dc.subject
Kavo Arcusdigma®
dc.subject
Maximum Opening
dc.subject
Temporomandibular Joint
dc.subject.classification
Otras Ingenierías y Tecnologías
dc.subject.classification
Otras Ingenierías y Tecnologías
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS
dc.title
Comparative study using video analysis and an ultrasonic measurement system to quantify mandibular movement
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2019-03-21T14:20:09Z
dc.identifier.eissn
2151-0903
dc.journal.volume
35
dc.journal.number
1
dc.journal.pagination
19-29
dc.journal.pais
Reino Unido
dc.journal.ciudad
Londres
dc.description.fil
Fil: Frisoli, Melisa Antonella. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; Argentina
dc.description.fil
Fil: Edelhoff, J. M.. Universität Göttingen; Alemania
dc.description.fil
Fil: Gersdorff, N.. Universität Göttingen; Alemania
dc.description.fil
Fil: Nicolet, Jonathan José Carlos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro de Investigaciones y Transferencia de Entre Ríos. Universidad Nacional de Entre Ríos. Centro de Investigaciones y Transferencia de Entre Ríos; Argentina
dc.description.fil
Fil: Braidot, Ariel Andrés Antonio. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; Argentina
dc.description.fil
Fil: Engelke, W.. Universität Göttingen; Alemania
dc.journal.title
The Journal of Craniomandibular Practice
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.tandfonline.com/doi/abs/10.1080/08869634.2015.1123376?journalCode=ycra20
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1080/08869634.2015.1123376