Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Artículo

Evaluation of EDXRF configurations to improve the limit of detection and exposure for in vivo quantification of gadolinium in tumor tissue

Santibáñez, M.; Vásquez, M.; Figueroa, R. G.; Valente, Mauro AndresIcon
Fecha de publicación: 05/2016
Editorial: Pergamon-Elsevier Science Ltd
Revista: Radiation Physics and Chemistry (Oxford)
ISSN: 0969-806X
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Otras Ciencias Físicas

Resumen

In this paper the configuration of an Energy Dispersive X-Ray Fluorescence (EDXRF) system optimized for in vivo quantification of gadolinium in tumor tissue was studied. The system was configured using XMI-MSIM software designed to predict the XRF spectral response using Monte Carlo simulations. The studied setup is comprised of an X-ray tube, tuned to different voltages, and a copper filter system configured with variable thickness, which emits a spectrally narrow beam centered on the specific excitation energy. The values for the central energy excitation and the spectral width were adjusted to optimize the system, using like figures of merit: minimization of the limit of detection, measurement uncertainty and radiation exposure. These values were obtained in two stages. The first was successive simulations of incident spectra with central energy in the range of 50-70keV. The second was comprised of simulations with incident spectra of different widths (8-29keV), all with the same determined central energy, evaluating the limit of detection depending on the exposure. This made it possible to find the best balance between system sensitivity and the delivered dose. The obtained results were compared with those produced by radioactive sources of 241Am whose activity was set to produce the same exposure as the proposed setup. To evaluate the feasibility of in vivo quantification, a set of tumor phantoms of 1-6cm3 at different depths and labeled with a gadolinium concentration of 250ppm was evaluated. From the resulting spectrum, calibration curves were obtained in function of the size and depth of the tumor, allowing for the evaluation of the potential of the methodology.
Palabras clave: Gadolinium , In Vivo Edxrf , Xmi-Msim
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 1.336Mb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Atribución-NoComercial-SinDerivadas 2.5 Argentina (CC BY-NC-ND 2.5 AR)
Identificadores
URI: http://hdl.handle.net/11336/71548
DOI: http://dx.doi.org/10.1016/j.radphyschem.2016.01.015
URL: https://www.sciencedirect.com/science/article/pii/S0969806X16300159
Colecciones
Articulos(IFEG)
Articulos de INST.DE FISICA ENRIQUE GAVIOLA
Citación
Santibáñez, M.; Vásquez, M.; Figueroa, R. G.; Valente, Mauro Andres; Evaluation of EDXRF configurations to improve the limit of detection and exposure for in vivo quantification of gadolinium in tumor tissue; Pergamon-Elsevier Science Ltd; Radiation Physics and Chemistry (Oxford); 122; 5-2016; 28-34
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES