Mostrar el registro sencillo del ítem

dc.contributor.author
Arkouli, Marcelina  
dc.contributor.author
Ulke, Ana Graciela  
dc.contributor.author
Endlicher, Wilfried  
dc.contributor.author
Baumbach, Günter  
dc.contributor.author
Schultz, Eckart  
dc.contributor.author
Vogt, Ulrich  
dc.contributor.author
Müller, Marlen  
dc.contributor.author
Dawidowski, Laura Elena  
dc.contributor.author
Faggi, Ana Maria  
dc.contributor.author
Wolf Benning, Uta  
dc.contributor.author
Scheffknecht, Günter  
dc.date.available
2019-01-31T16:34:27Z  
dc.date.issued
2010-12  
dc.identifier.citation
Arkouli, Marcelina; Ulke, Ana Graciela; Endlicher, Wilfried; Baumbach, Günter; Schultz, Eckart; et al.; Distribution and temporal behavior of particulate matter over the urban area of Buenos Aires; Dokuz Eylul Universitesi; Atmospheric Pollution Research; 1; 1; 12-2010; 1-8  
dc.identifier.issn
1309-1042  
dc.identifier.uri
http://hdl.handle.net/11336/69103  
dc.description.abstract
This paper contributes for the first time in Buenos Aires city to the temporal and horizontal distribution of the PM2.5 and PM10 concentrations. Their variations and relationships with relevant variables that characterize the air pollution potential of the urban air shed are also given. The measurements were carried out for one year from May 2006 to May 2007. During this period, particulate matter (PM) was continuously measured at one reference station and alternatively for shorter time periods at six different sites. The values and temporal variations on a daily and seasonal basis were consistent with the ventilation potential of the atmosphere. The cold season, which had the lowest values of the ventilation coefficient, indicated higher probabilities of poor air quality and this was confirmed by the higher concentrations of PM10 and PM2.5 measured. At the reference station, the daily EU limit value for PM10 was exceeded 36 times during one year while the Buenos Aires limit value was exceeded only once. The PM10 annual mean value was almost 70% of the Buenos Aires annual limit. The PM2.5 annual mean value (15 μg m-3) was same as the regulated one (15 μg m-3). The correlation between PM10 and PM2.5 concentrations and frequencies of wind directions showed that the highest concentrations were observed when the wind was from the city (land wind) and lowest concentrations when the wind was from Rio de La Plata (fluvial wind). The concentrations during land wind events exceeded the Buenos Aires PM2.5 annual limit value. The ratio of PM2.5 to PM10 was 0.44, which indicates the coarse particles (>2.5 μm) originated from road dust, soil re-suspension and abrasion processes are the dominated fractions of PM. Results of random PM measurements at 60 sites showed that PM2.5 was more homogeneously distributed over the city than PM10.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Dokuz Eylul Universitesi  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/  
dc.subject
Air Quality Monitoring  
dc.subject
Field Campaign  
dc.subject
Urban Air Pollution  
dc.subject.classification
Otras Ciencias Biológicas  
dc.subject.classification
Ciencias Biológicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Distribution and temporal behavior of particulate matter over the urban area of Buenos Aires  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2019-01-30T13:59:27Z  
dc.journal.volume
1  
dc.journal.number
1  
dc.journal.pagination
1-8  
dc.journal.pais
Turquía  
dc.description.fil
Fil: Arkouli, Marcelina. Universität Stuttgart; Alemania  
dc.description.fil
Fil: Ulke, Ana Graciela. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Departamento de Ciencias de la Atmósfera y los Océanos; Argentina  
dc.description.fil
Fil: Endlicher, Wilfried. Universität zu Berlin; Alemania  
dc.description.fil
Fil: Baumbach, Günter. Universität Stuttgart; Alemania  
dc.description.fil
Fil: Schultz, Eckart. Deutscher Wetterdienst; Alemania  
dc.description.fil
Fil: Vogt, Ulrich. Universität Stuttgart; Alemania  
dc.description.fil
Fil: Müller, Marlen. Universität zu Berlin; Alemania  
dc.description.fil
Fil: Dawidowski, Laura Elena. Comisión Nacional de Energía Atómica; Argentina  
dc.description.fil
Fil: Faggi, Ana Maria. Universidad de Flores; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina  
dc.description.fil
Fil: Wolf Benning, Uta. Universität zu Berlin; Alemania  
dc.description.fil
Fil: Scheffknecht, Günter. Universität Stuttgart; Alemania  
dc.journal.title
Atmospheric Pollution Research  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.5094/APR.2010.001  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S1309104215305559