dc.description.abstract
Experimental curves of erythrocyte aggregation were modelled and fitted to obtain representative parameters of aggregation kinetics. Blood from healthy donors was collected and samples were prepared and analyzed at 40% hematocrit. Data were obtained by an optical chip aggregometer developed in our laboratory and based on light transmission. Curves, representing plots of transmitted light through a blood sample against time were recorded and subjected to custom made software in order to obtain characteristic parameters of the aggregation phenomenon. This study is of importance in biomedicine since it helps to develop simple tools and techniques for blood characterization, especially concerning vascular pathologies such as hypertension and diabetes, where the red blood cell aggregation phenomenon is altered.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Bulgarian Academy of Sciences. Institute of Mechanics
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
Erythrocyte Aggregation
dc.subject
Computational Model
dc.subject
Light Transmission
dc.subject
Optical Chip
dc.subject.classification
Astronomía
dc.subject.classification
Ciencias Físicas
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS
dc.title
Computational analysis of red blood cell aggregation kinetics to obtain representative parameters in healthy donors
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2018-10-23T16:35:27Z
dc.journal.volume
31
dc.journal.number
3
dc.journal.pagination
36-41
dc.journal.pais
Bulgaria
dc.journal.ciudad
Sofía
dc.description.fil
Fil: Ciunne, M. F.. No especifica;
dc.description.fil
Fil: Toderi Cicchini, Martín Alejandro. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario. Instituto de Física de Rosario. Universidad Nacional de Rosario. Instituto de Física de Rosario; Argentina
dc.description.fil
Fil: Riquelme, Bibiana Doris. No especifica;
dc.journal.title
Series on Biomechanics
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://jsb.imbm.bas.bg/page/en/details.php?article_id=244
Archivos asociados