dc.description.abstract
Nonlinear dielectric spectroscopy of micro-organism is carried out by applying a moderate electrical field to an aqueous sample through two metal electrodes. Several ad hoc nonlinear spectrometers were proposed in the literature. However, these designs barely compensated the nonlinear distortion derived from the electrode-electrolyte interfaces (EEI). Moreover, the contribution of the suspension is masked by the effect of the nonlinearity introduced by the electrode contacts. Conversely, the nonlinear capability of a commercial tetrapolar analyzer has not been fully investigated. In this paper a new nonlinear tetrapolar spectrometer is proposed based on a commercial linear apparatus and ad hoc control and signal processing software. The system was evaluated with discrete electronic phantoms and showed that it can measure nonlinear properties of aqueous suspension independently of the presence of EEI (ANOVA test, p0.001). It was also tested with real aqueous samples. The harmonics observed in the current that circulates through the sample reveals useful information about the transfer function of the sample. The total harmonic distortion was computed for linear mediums. Values lower than -60 dB suggest that the system has enough capability to perform nonlinear microbiological analysis. Design specifications, sources of interference, and equipment's limitations are discussed.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
American Institute of Physics  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
Biological  
dc.subject
Impedance  
dc.subject
Suspension  
dc.subject.classification
Ingeniería de Sistemas y Comunicaciones  
dc.subject.classification
Ingeniería Eléctrica, Ingeniería Electrónica e Ingeniería de la Información  
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS  
dc.title
Design and evaluation of a fast Fourier transform-based nonlinear dielectric spectrometer  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2018-11-13T17:09:04Z  
dc.journal.volume
80  
dc.journal.number
11  
dc.journal.pagination
114301-114308  
dc.journal.pais
Estados Unidos  
dc.journal.ciudad
New York  
dc.description.fil
Fil: Treo, Ernesto Federico. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Bioingeniería; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de San Juan; Argentina  
dc.description.fil
Fil: Felice, Carmelo Jose. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; Argentina  
dc.journal.title
Review of Scientific Instruments  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://aip.scitation.org/doi/10.1063/1.3247903  