Mostrar el registro sencillo del ítem
dc.contributor.author
Hernández, Alejandro Luis
dc.contributor.author
Quiñonez, José Eduardo
dc.date.available
2018-11-28T15:13:39Z
dc.date.issued
2018-03
dc.identifier.citation
Hernández, Alejandro Luis; Quiñonez, José Eduardo; Experimental validation of an analytical model for performance estimation of natural convection solar air heating collectors; Pergamon-Elsevier Science Ltd; Renewable Energy; 117; 3-2018; 202-216
dc.identifier.issn
0960-1481
dc.identifier.uri
http://hdl.handle.net/11336/65423
dc.description.abstract
In this paper, the experimental validation of an analytical model that describes the thermal behaviour of double parallel flow air heating collectors working by natural convection is presented. This model was validated with data measured on a collector of these characteristics at the National University of Salta, in the northwest of Argentina. Comparisons between measured and simulated values show an excellent agreement for both the air output temperature and the useful energy produced by the collector, with RMSE values smaller than 6%. The instantaneous thermal efficiency curve of the collector was determined experimentally in winter of 2015. Daily values of efficiency ranged between 0.48 and 0.5 during sunny days, and between 0.41 and 0.46 during semi-cloudy days. A novel correlation between the velocity of the air movement by natural convection and the temperature difference between the building and the collector's interior was obtained by means of linear regression with a correlation coefficient R2 = 0.94. A new correlation Nu = f(Ra) to estimate the average convective coefficients by natural convection was obtained, based on an effective convective heat transfer coefficient calculated with the temperature values measured inside the collector and the absorbed solar irradiance.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Pergamon-Elsevier Science Ltd
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
Experimental Validation
dc.subject
Mathematical Modelling
dc.subject
Solar Air Collector
dc.subject.classification
Otras Ingenierías y Tecnologías
dc.subject.classification
Otras Ingenierías y Tecnologías
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS
dc.title
Experimental validation of an analytical model for performance estimation of natural convection solar air heating collectors
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2018-10-23T17:30:19Z
dc.journal.volume
117
dc.journal.pagination
202-216
dc.journal.pais
Estados Unidos
dc.journal.ciudad
Nueva York
dc.description.fil
Fil: Hernández, Alejandro Luis. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Salta. Instituto de Investigaciones en Energía no Convencional. Universidad Nacional de Salta. Facultad de Ciencias Exactas. Departamento de Física. Instituto de Investigaciones en Energía no Convencional; Argentina
dc.description.fil
Fil: Quiñonez, José Eduardo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Salta. Instituto de Investigaciones en Energía no Convencional. Universidad Nacional de Salta. Facultad de Ciencias Exactas. Departamento de Física. Instituto de Investigaciones en Energía no Convencional; Argentina
dc.journal.title
Renewable Energy
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0960148117309503
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/https://dx.doi.org/10.1016/j.renene.2017.09.082
Archivos asociados