Mostrar el registro sencillo del ítem

dc.contributor.author
Colombo, Lucas  
dc.contributor.author
Garay, Fernando Sebastian  
dc.date.available
2018-11-13T18:03:31Z  
dc.date.issued
2017-10  
dc.identifier.citation
Colombo, Lucas; Garay, Fernando Sebastian; A robust and practically free of charge intermittent use glucose biosensor; Elsevier Science Sa; Sensors and Actuators B: Chemical; 256; 10-2017; 751-759  
dc.identifier.issn
0925-4005  
dc.identifier.uri
http://hdl.handle.net/11336/64341  
dc.description.abstract
In the past decades, great effort has been put in finding new electrode surface modifiers and enzyme immobilizer agents that prevent the enzyme leakage, minimize the effect of interfering species, retain the enzyme bioactivity, and enhance the sensor sensitivity. In this work, a sandwich-type glucose biosensor that keeps its sensitivity and operational linear range for more than a year is presented. After 5 months of intermittent use, where the biosensor was exposed to more than 500 standard additions, it presented a limit of detection of 5 μM, and the linear behavior was from 5 μM to 3 mM with a value of r2 = 0.999. Besides, after 7 months of its assembling, the biosensor was employed for assessing the glucose concentration of real serum samples and its performance was compared with the response of a commercial autoanalyzer. A year later, the biosensor still exhibited very good performance of its analytical parameters. The performance of identical sandwich-type biosensors is analyzed when they are exposed to three different storage conditions. Simulated curves are compared with experimental data to explain the dependence of sensitivity and response-time on the aging and storage conditions of the biosensors.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Elsevier Science Sa  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
Biosensor  
dc.subject
Chronoamperometry  
dc.subject
Diabetes  
dc.subject
Glucose  
dc.subject
Intermittent Use  
dc.subject
Long-Term Stability  
dc.subject.classification
Otras Ciencias Químicas  
dc.subject.classification
Ciencias Químicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
A robust and practically free of charge intermittent use glucose biosensor  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2018-10-22T18:37:11Z  
dc.journal.volume
256  
dc.journal.pagination
751-759  
dc.journal.pais
Países Bajos  
dc.journal.ciudad
Amsterdam  
dc.description.fil
Fil: Colombo, Lucas. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina  
dc.description.fil
Fil: Garay, Fernando Sebastian. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina  
dc.journal.title
Sensors and Actuators B: Chemical  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/https://dx.doi.org/10.1016/j.snb.2017.10.010  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://linkinghub.elsevier.com/retrieve/pii/S0925400517318907