Mostrar el registro sencillo del ítem

dc.contributor.author
Springer, Valeria Haydee  
dc.contributor.author
Lista, Adriana Guillermina  
dc.date.available
2018-11-08T20:09:48Z  
dc.date.issued
2010-11  
dc.identifier.citation
Springer, Valeria Haydee; Lista, Adriana Guillermina; A simple and fast method for chlorsulfuron and metsulfuron methyl determination in water samples using multiwalled carbon nanotubes (MWCNTs) and capillary electrophoresis; Elsevier Science; Talanta; 83; 1; 11-2010; 126-129  
dc.identifier.issn
0039-9140  
dc.identifier.uri
http://hdl.handle.net/11336/64027  
dc.description.abstract
A new method to determine metsulfuron methyl (MSM) and chlorsulfuron (CS) in different water samples was developed. It consists in a solid phase extraction (SPE) procedure using multiwalled carbon nanotubes (MWCNTs) as sorbent material in combination with capillary zone electrophoretic determination. To carry out the pre-concentration step, a simple flow injection system was developed and optimized. Thus, 250 μL of aqueous solution containing methanol 50% (v/v) and acetonitrile 2% (v/v) as eluent, 10 mL of sample and a flow rate of 1.15 mL min-1 were selected. The CE variables also were optimized. A rapid determination and good resolution of two herbicides were obtained within 9 min using a simple electrophoretic buffer (50 mmol L-1 sodium tetraborate with 3% of methanol, pH = 9.0). Under the optimum conditions, the calibration curves were linear between 0.5 and 6 μg L-1 for MSM and CS with R2 = 0.995 and 0.997, respectively. The repeatability of the proposed method, expressed as relative standard deviation (RSD), varied between 4.1% and 5.4% (n = 10) and the detection limits for MSM and CS were 0.40 and 0.36 μg L-1, respectively. Good results were achieved when the proposed method was applied to spiked real water samples. The recoveries percentages of the two analytes were over the range 86-108%. © 2010 Elsevier B.V.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Elsevier Science  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
Capillary Zone Electrophoresis  
dc.subject
Carbon Nanotubes  
dc.subject
Chlorsulfuron  
dc.subject
Metsulfuron Methyl  
dc.subject
Solid Phase Extraction  
dc.subject.classification
Otras Ciencias Químicas  
dc.subject.classification
Ciencias Químicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
A simple and fast method for chlorsulfuron and metsulfuron methyl determination in water samples using multiwalled carbon nanotubes (MWCNTs) and capillary electrophoresis  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2018-11-05T19:14:25Z  
dc.journal.volume
83  
dc.journal.number
1  
dc.journal.pagination
126-129  
dc.journal.pais
Países Bajos  
dc.journal.ciudad
Amsterdam  
dc.description.fil
Fil: Springer, Valeria Haydee. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Química del Sur. Universidad Nacional del Sur. Departamento de Química. Instituto de Química del Sur; Argentina  
dc.description.fil
Fil: Lista, Adriana Guillermina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Química del Sur. Universidad Nacional del Sur. Departamento de Química. Instituto de Química del Sur; Argentina  
dc.journal.title
Talanta  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0039914010006880  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/https://dx.doi.org/10.1016/j.talanta.2010.08.049