Mostrar el registro sencillo del ítem

dc.contributor.author
Marozzi, Carlos A.  
dc.contributor.author
Gennero, Maria Rosa  
dc.contributor.author
Chialvo, Abel Cesar  
dc.date.available
2016-07-07T20:11:05Z  
dc.date.issued
2013-09  
dc.identifier.citation
Marozzi, Carlos A.; Gennero, Maria Rosa; Chialvo, Abel Cesar; Analysis of the applicability of short time chronoamperometry for the kinetic study of the hydrogen oxidation reaction; Elsevier; Electrochimica Acta; 112; 9-2013; 68-73  
dc.identifier.issn
0013-4686  
dc.identifier.uri
http://hdl.handle.net/11336/6391  
dc.description.abstract
This work analyses the applicability of the chronoamperometric method for the evaluation of the kinetic parameters of the hydrogen oxidation reaction. It consists in the application of an overpotential step and the subsequent plot of the current density response against the square root of time. The extrapolation of the resulting straight line at short times is assigned to the kinetic current density at such overpotential. Then, from the polarization curve, the parameters exchange current density and Tafel slope are evaluated. This method is only strictly valid for simple reactions without adsorbed intermediates. Therefore, a complete analysis that takes into account all the phenomena involved, including the effect of the pseudocapacitive current due to the adsorbed hydrogen, is carried out. The results obtained confirm the inapplicability of the chronoamperometric method for the kinetic study of the hydrogen oxidation reaction.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Elsevier  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/  
dc.subject
Chronoamperometry  
dc.subject
Hydrogen Oxidation Reaction  
dc.subject
Kinetic Parameters  
dc.subject
Pseudocapacitive Current  
dc.subject.classification
Ingeniería Química  
dc.subject.classification
Ingeniería Química  
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS  
dc.title
Analysis of the applicability of short time chronoamperometry for the kinetic study of the hydrogen oxidation reaction  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2016-07-06T15:47:53Z  
dc.journal.volume
112  
dc.journal.pagination
68-73  
dc.journal.pais
Países Bajos  
dc.journal.ciudad
Amsterdam  
dc.description.fil
Fil: Marozzi, Carlos A.. Universidad Nacional del Litoral. Facultad de Ingeniería Química. Programa de Electroquímica Aplicada e Ingeniería Electroquímica; Argentina  
dc.description.fil
Fil: Gennero, Maria Rosa. Universidad Nacional del Litoral. Facultad de Ingeniería Química. Programa de Electroquímica Aplicada e Ingeniería Electroquímica; Argentina  
dc.description.fil
Fil: Chialvo, Abel Cesar. Universidad Nacional del Litoral. Facultad de Ingeniería Química. Programa de Electroquímica Aplicada e Ingeniería Electroquímica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Santa Fe; Argentina  
dc.journal.title
Electrochimica Acta  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S0013468613015971  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.electacta.2013.08.068  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/10.1016/j.electacta.2013.08.068