Mostrar el registro sencillo del ítem

dc.contributor.author
Pagani, Ariana Paula  
dc.contributor.author
Ibañez, Gabriela Alejandra  
dc.date.available
2018-11-07T17:33:17Z  
dc.date.issued
2017-05  
dc.identifier.citation
Pagani, Ariana Paula; Ibañez, Gabriela Alejandra; Four-way calibration applied to the processing of pH-modulated fluorescence excitation-emission matrices. Analysis of fluoroquinolones in the presence of significant spectral overlapping; Elsevier Science; Microchemical Journal; 132; 5-2017; 211-218  
dc.identifier.issn
0026-265X  
dc.identifier.uri
http://hdl.handle.net/11336/63890  
dc.description.abstract
A new methodology involving four-way multivariate calibration with a balanced number of data points in all modes is presented. The method is based on fluorescence excitation-emission matrices modulated by a double pH gradient obtained in a flow injection system. This data array was employed for the quantitation of ciprofloxacin, ofloxacin and norfloxacin in unprocessed urine samples. Due to the presence of potential interfering compounds with overlapping profiles in the analyzed samples, it is required to achieve the second-order advantage. The four-way arrays obtained were processed by parallel factor analysis (PARAFAC), attaining satisfactory results with relative errors of prediction (REP%) between 3% and 7.5% in the analyzed samples for all analytes. The average limit of detection (mg L− 1) was 0.035 for norfloxacin and ofloxacin and 0.028 for ciprofloxacin.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Elsevier Science  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/  
dc.subject
Excitation-Emission Fluorescence Matrices  
dc.subject
Fluoroquinolones  
dc.subject
Parafac  
dc.subject
Ph-Gradient  
dc.subject
Third-Order Multivariate Analysis  
dc.subject.classification
Otras Ciencias Químicas  
dc.subject.classification
Ciencias Químicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Four-way calibration applied to the processing of pH-modulated fluorescence excitation-emission matrices. Analysis of fluoroquinolones in the presence of significant spectral overlapping  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2018-10-23T17:33:55Z  
dc.journal.volume
132  
dc.journal.pagination
211-218  
dc.journal.pais
Países Bajos  
dc.journal.ciudad
Amsterdam  
dc.description.fil
Fil: Pagani, Ariana Paula. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario. Instituto de Química Rosario. Universidad Nacional de Rosario. Facultad de Ciencias Bioquímicas y Farmacéuticas. Instituto de Química Rosario; Argentina  
dc.description.fil
Fil: Ibañez, Gabriela Alejandra. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario. Instituto de Química Rosario. Universidad Nacional de Rosario. Facultad de Ciencias Bioquímicas y Farmacéuticas. Instituto de Química Rosario; Argentina  
dc.journal.title
Microchemical Journal  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.microc.2017.01.028  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0026265X1630371X