Mostrar el registro sencillo del ítem

dc.contributor.author
Catuogno, Guillermo Ricardo  
dc.contributor.author
Garcia, Guillermo  
dc.contributor.author
Leidhold, Roberto  
dc.date.available
2018-10-18T18:09:01Z  
dc.date.issued
2015-11  
dc.identifier.citation
Catuogno, Guillermo Ricardo; Garcia, Guillermo; Leidhold, Roberto; Fault-Tolerant inverter for Power Flow Control in Variable-Speed Four-Wire Permanent-Magnet Generators; Institute of Electrical and Electronics Engineers; Ieee Transactions On Industrial Electronics; 62; 11; 11-2015; 6727-6736  
dc.identifier.issn
0278-0046  
dc.identifier.uri
http://hdl.handle.net/11336/62714  
dc.description.abstract
A strategy for fault detection and tolerance on the inverter that controls power flow in variable-speed permanent-magnet generators is proposed in this paper. The performance of the proposed strategy is analyzed in two different four-wire topologies. In the first topology, the neutral point of the generator is connected to the middle point of the dc-link capacitor bank, whereas in the second topology, it is connected to a fourth leg of the inverter. The main contribution of this paper resides in the control scheme, which allows a steady operation through a fault occurrence without the need of reconfiguring neither the inverter topology nor the control algorithm. In this way, transients and the use of extra hardware components are avoided. In addition, a control loop that allows limiting the generator losses at any operation point is presented in order to protect the machine. Finally, experimental results, obtained from a laboratory prototype, validate the practical feasibility of the proposed strategy.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Institute of Electrical and Electronics Engineers  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
Fault Tolerance  
dc.subject
Four-Wire Topologies  
dc.subject
Permanent-Magnet Generators  
dc.subject.classification
Ingeniería de Sistemas y Comunicaciones  
dc.subject.classification
Ingeniería Eléctrica, Ingeniería Electrónica e Ingeniería de la Información  
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS  
dc.title
Fault-Tolerant inverter for Power Flow Control in Variable-Speed Four-Wire Permanent-Magnet Generators  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2018-03-02T17:33:11Z  
dc.journal.volume
62  
dc.journal.number
11  
dc.journal.pagination
6727-6736  
dc.journal.pais
Estados Unidos  
dc.description.fil
Fil: Catuogno, Guillermo Ricardo. Universidad Nacional de San Luis. Facultad de Ingeniería y Ciencias Agropecuarias. Laboratorio de Control Automático; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina  
dc.description.fil
Fil: Garcia, Guillermo. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de Rio Cuarto. Facultad de Ingeniería. Grupo de Electronica Aplicada; Argentina  
dc.description.fil
Fil: Leidhold, Roberto. Otto-von-Guericke-Universität Magdeburg; Alemania  
dc.journal.title
Ieee Transactions On Industrial Electronics  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1109/TIE.2015.2438771  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://ieeexplore.ieee.org/document/7115071