Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Artículo

Dispositivos poliméricos sólidos de aplicación oftálmica

Calles, Javier AdriánIcon ; Valles, Enrique MarceloIcon ; Llabot, Juan ManuelIcon ; Palma, Santiago DanielIcon
Fecha de publicación: 04/2012
Editorial: Rasgo Editorial
Revista: Atencion Farmaceutica
ISSN: 1139-7357
Idioma: Español
Tipo de recurso: Artículo publicado
Clasificación temática:
Farmacología y Farmacia

Resumen

 
Los SPF oftálmicos son un interesante desafío para la farmacotecnia moderna. La anatomía, fisiología y bioquímica del ojo complican el acceso de fármacos a tejidos intraoculares. El objetivo central es casi siempre lograr sistemas portadores que superen las barreras protectoras de este órgano sin causar danos tisulares graves ni permanentes. Las formas farmacéuticas tradicionales (soluciones, suspensiones y ungüentos) presentan limitaciones para resolver una gran cantidad de patologías oculares que se presentan en la actualidad. Estas limitaciones se deben principalmente a la perdida rápida y extensiva de la formulación del área precorneal en virtud del drenaje, el parpadeo y del re-cambio lagrimal. Una alternativa para aumentar el tiempo de residencia de las formulaciones en la zona de aplicación es el uso de sistemas bioadhesivos. El Acido Hialuronico (HA) es un polisacárido lineal de alto PM formado por acido (3-D-glucuronico y N-acetil-p-D-glucosamina, ampliamente distribuido en el organismo (fluido sinovial, piel, cordón umbilical y humor vítreo), frecuente-mente utilizado para el tratamiento de patologías como osteoartritis, quemaduras y cirugía oftálmica. Sus propiedades de biocompatibilidad y biodegradabilidad hacen del mismo un biomaterial prometedor para el diseño de sistemas portado-res de fármacos de aplicación tópica. En este trabajo se presentan estudios preliminares para evaluar las propieda¬des mecánicas, bioadhesivas y de humectación de films de HA y HA químicamente modificados con GTA y con el agregado de plastificantes como la Triacetina (TA) y el Polietilenglicol 400 (PEG).
 
Ophthalmic SPFs (Side Polished Fibers) are an interesting challenge for modern pharmaceutical technique. The eye s anatomy, physiology and biochemistry make it difficult for drugs to access intraocular tissues. The main objective is almost always to obtain carrying systems that overcome the eye s protective barriers without causing severe or permanent tissular damage. The traditional pharmaceutical forms (solutions, suspensions and ointments) have certain limitations for resolving a large number of ocular pathologies that currently occur. Such limitations are mainly due to the rapid and extensive loss of the precorneal area's formulation due to drainage, blinking and lachrymal secretion. The use of bioadhesive systems is an alternative to increase the formulation s time of presence on the application area Hyaluronic acid (HA) is a high-molecular-weight linear polysaccharide composed of/5-Dglucuronic acid and N-acetyl- fl-D-glucosamine widely distributed in the organism (synovial fluid, skin, umbilical cord and vitreous humor), frequently used for the treatment of pathologies like osteoarthritis, burns and ophthalmic surgery. Its biocompatibility and biodegradability properties make it a promising biomaterial for the design of carrying systems for topical application drugs.
 
Palabras clave: Liberación , Oftálmico , Hialurónico , Biopolímeros
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 11.50Mb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/62652
URL: http://www.pharmcareesp.com/index.php/PharmaCARE/issue/view/1
Colecciones
Articulos(CCT - CORDOBA)
Articulos de CTRO.CIENTIFICO TECNOL.CONICET - CORDOBA
Articulos(PLAPIQUI)
Articulos de PLANTA PILOTO DE INGENIERIA QUIMICA (I)
Citación
Calles, Javier Adrián; Valles, Enrique Marcelo; Llabot, Juan Manuel; Palma, Santiago Daniel; Dispositivos poliméricos sólidos de aplicación oftálmica; Rasgo Editorial; Atencion Farmaceutica; 14; 2; 4-2012; 116-122
Compartir

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES