Montemurro, Milagros; de Zan, María Mercedes; Robles, Juan Carlos; Optimized high performance liquid chromatography-ultraviolet detection method using core-shell particles for the therapeutic monitoring of methotrexate; Xi'an Jiaotong University; Journal of Pharmaceutical Analysis; 6; 2; 4-2016; 103-111  
dc.identifier.issn
2095-1779  
dc.identifier.uri
http://hdl.handle.net/11336/62332  
dc.description.abstract
Methotrexate (MTX) is an antineoplastic drug, and due to its high toxicity, the therapeutic drug monitoring is strictly conducted in the clinical practice. The chemometric optimization and validation of a high performance liquid chromatography (HPLC) method using core-shell particles is presented for the determination of MTX in plasma during therapeutic monitoring. Experimental design and response surface methodology (RSM) were applied for the optimization of the chromatographic system and the analyte extraction step. A Poroshell 120 EC-C18 (3.0 mm×75 mm, 2.7 μm) column was used to obtain a fast and efficient separation in a complete run time of 4 min. The optimum conditions for the chromatographic system resulted in a mobile phase consisting of acetic acid/sodium acetate buffer solution (85.0 mM, pH=4.00) and 11.2% of acetonitrile at a flow rate of 0.4 mL/min. Selectivity, linearity, accuracy and precision were demonstrated in a range of 0.10-6.0 μM of MTX. The application of the optimized method required only 150 μL of patient plasma and a low consumption of solvent to provide rapid results.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Xi'an Jiaotong University  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
Core-Shell Particles  
dc.subject
Drug Monitoring  
dc.subject
Hplc  
dc.subject
Methotrexate  
dc.subject.classification
Otras Ciencias Químicas  
dc.subject.classification
Ciencias Químicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Optimized high performance liquid chromatography-ultraviolet detection method using core-shell particles for the therapeutic monitoring of methotrexate  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2018-10-11T17:40:20Z  
dc.journal.volume
6  
dc.journal.number
2  
dc.journal.pagination
103-111  
dc.journal.pais
Países Bajos  
dc.journal.ciudad
Amsterdam  
dc.description.fil
Fil: Montemurro, Milagros. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; Argentina. Universidad Nacional del Litoral. Facultad de Bioquímica y Ciencias Biológicas; Argentina  
dc.description.fil
Fil: de Zan, María Mercedes. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; Argentina. Universidad Nacional del Litoral. Facultad de Bioquímica y Ciencias Biológicas; Argentina  
dc.description.fil
Fil: Robles, Juan Carlos. Universidad Nacional del Litoral. Facultad de Bioquímica y Ciencias Biológicas; Argentina  
dc.journal.title
Journal of Pharmaceutical Analysis  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1016/j.jpha.2015.12.001  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://linkinghub.elsevier.com/retrieve/pii/S2095177915300186