Mostrar el registro sencillo del ítem
dc.contributor.author
Benavidez, Tomás Enrique
dc.contributor.author
Baruzzi, Ana Maria
dc.date.available
2018-10-05T19:03:13Z
dc.date.issued
2012-01
dc.identifier.citation
Benavidez, Tomás Enrique; Baruzzi, Ana Maria; Comparative behavior of glucose oxidase and oxalate oxidase immobilized in mucin/chitosan hydrogels for biosensors applications; Elsevier; Polymer; 53; 2; 1-2012; 438-444
dc.identifier.issn
0032-3861
dc.identifier.uri
http://hdl.handle.net/11336/61792
dc.description.abstract
The analytical response of amperometric glucose electrodes was explained in the framework of the properties of hydrogels with different muc/chit ratio at pH = 7.00 used as immobilization matrix for glucose oxidase. The continuous increase in the sensitivity of the electrodes with the amount of chitosan was attributed to a more efficient crosslinking without affecting the enzyme activity. The results were compared with those obtained using the same matrices to immobilize Oxalate Oxidase at pH = 2.85 where it has the highest activity. A maximum sensitivity at muc/chit 70/30 ratio for these oxalate electrodes was observed. Decrease in permeability of negatively charged oxalate with the chitosan content in the matrices, in spite of the high partition coefficient, explains the analytical differences with glucose electrodes. Swelling and viscoelasticity of the hydrogels allowed to asses the importance of a hydrophilic environment for the enzyme in both cases. © 2011 Elsevier Ltd. All rights reserved.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Elsevier
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
Biosensor
dc.subject
Enzymes
dc.subject
Hydrogel
dc.subject.classification
Otras Ciencias Químicas
dc.subject.classification
Ciencias Químicas
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS
dc.title
Comparative behavior of glucose oxidase and oxalate oxidase immobilized in mucin/chitosan hydrogels for biosensors applications
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2018-09-18T16:16:27Z
dc.journal.volume
53
dc.journal.number
2
dc.journal.pagination
438-444
dc.journal.pais
Países Bajos
dc.journal.ciudad
Amsterdam
dc.description.fil
Fil: Benavidez, Tomás Enrique. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina
dc.description.fil
Fil: Baruzzi, Ana Maria. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina
dc.journal.title
Polymer
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/https://www.sciencedirect.com/science/article/pii/S0032386111010202
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/https://dx.doi.org/10.1016/j.polymer.2011.12.014
Archivos asociados