Artículo
Four-way multivariate calibration using ultra-fast High-Performance Liquid Chromatography with Fluorescence Excitation-Emission detection. Application to the direct analysis of chlorophylls a and b and pheophytins a and b in olive oils
Lozano, Valeria Antonella
; Muñoz de la Peña, Arsenio; Durán Merás, Isabel; Espinosa Mansilla, Anunciación; Escandar, Graciela Monica
Fecha de publicación:
06/2013
Editorial:
Elsevier
Revista:
Chemometrics and Intelligent Laboratory Systems
ISSN:
0169-7439
Idioma:
Inglés
Tipo de recurso:
Artículo publicado
Clasificación temática:
Resumen
A four-way multivariate calibration approach, based on the combination of ultra-fast high-performance liquid chromatographic data and four-way algorithms, is described for the first time. To achieve this goal, several emission wavelength-elution time matrices (ETMs) were recorded as a function of the excitation wavelength. Each sample was injected into the chromatograph eight times, in sequential mode, each time exciting at a different wavelength across the excitation spectra of the compounds of interest, and the emission spectra were recorded along the full chromatogram using a fast scanning fluorescence detector. The data were obtained in a very short time with an ultrafast chromatographic system operating in gradient mode. The three-way ETM data thus obtained for the calibration sample set and for each of the test samples were joined into a single four-way array, which was subsequently analyzed with parallel factor analysis (PARAFAC), unfolded partial least-squares with residual trilinearization (U-PLS/RTL) and multi-way partial least-squares with residual trilinearization (N-PLS/RTL) multivariate calibration algorithms. Best results were found when either U-PLS/RTL or N-PLS/RTL algorithms were used to perform the multivariate calibration. The method was applied to the direct determination of chlorophylls a and b and pheophytins a and b in olive oil samples, in the presence of other interfering fluorescent compounds, and without previous sample treatment.
Archivos asociados
Licencia
Identificadores
Colecciones
Articulos(IQUIR)
Articulos de INST.DE QUIMICA ROSARIO
Articulos de INST.DE QUIMICA ROSARIO
Citación
Lozano, Valeria Antonella; Muñoz de la Peña, Arsenio; Durán Merás, Isabel; Espinosa Mansilla, Anunciación; Escandar, Graciela Monica; Four-way multivariate calibration using ultra-fast High-Performance Liquid Chromatography with Fluorescence Excitation-Emission detection. Application to the direct analysis of chlorophylls a and b and pheophytins a and b in olive oils; Elsevier; Chemometrics and Intelligent Laboratory Systems; 125; 6-2013; 121-131
Compartir