Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Artículo

Second-order advantage with excitation-emission photoinduced fluorimetry for the determination of the antiepileptic carbamazepine in environmental waters

Escandar, Graciela MonicaIcon ; Lozano, Valeria AntonellaIcon
Fecha de publicación: 06/2013
Editorial: Elsevier
Revista: Analytica Chimica Acta
ISSN: 0003-2670
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Química Analítica

Resumen

A photochemically-induced fluorescence system combined with second-order chemometric analysis for the determination of the anticonvulsant carbamazepine (CBZ) is presented. CBZ is a widely used drug for the treatment of epilepsy and is included in the group of emerging contaminant present in the aquatic environment. CBZ is not fluorescent in solution but can be converted into a fluorescent compound through a photochemical reaction in a strong acid medium. The determination is carried out by measuring excitation-emission photoinduced fluorescence matrices of the products formed upon ultraviolet light irradiation in a laboratory-constructed reactor constituted by two simple 4 W germicidal tubes. Working conditions related to both the reaction medium and the photoreactor geometry are optimized by an experimental design. The developed approach enabled the determination of CBZ at trace levels without the necessity of applying separation steps, and in the presence of uncalibrated interferences which also display photoinduced fluorescence and may be potentially present in the investigated samples. Different second-order algorithms were tested and successful resolution was achieved using multivariate curve resolution-alternating least-squares (MCR-ALS). The study is employed for the discussion of the scopes and yields of each of the applied second-order chemometric tools. The quality of the proposed method is probed through the determination of the studied emerging pollutant in both environmental and drinking water samples. After a pre-concentration step on a C18 membrane using 50.0 mL of real water samples, a prediction relative error of 2 % and limits of detection and quantification of 0.2 and 0.6 ng mL-1 were respectively obtained.
Palabras clave: Photoinduced Fluorescence , Multivariate Calibration , Carbamazepine
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 1.644Mb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Atribución-NoComercial-SinDerivadas 2.5 Argentina (CC BY-NC-ND 2.5 AR)
Identificadores
URI: http://hdl.handle.net/11336/6025
URL: http://www.sciencedirect.com/science/article/pii/S000326701300531X
DOI: http://dx.doi.org/ 10.1016/j.aca.2013.04.020
DOI: http://dx.doi.org/10.1016/j.aca.2013.04.020
Colecciones
Articulos(IQUIR)
Articulos de INST.DE QUIMICA ROSARIO
Citación
Escandar, Graciela Monica; Lozano, Valeria Antonella; Second-order advantage with excitation-emission photoinduced fluorimetry for the determination of the antiepileptic carbamazepine in environmental waters; Elsevier; Analytica Chimica Acta; 782; 6-2013; 37-45
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES