Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Artículo

Small-loop electromagnetic induction for environmental studies at industrial plants

Martinelli, Hilda PatriciaIcon ; Osella, Ana MariaIcon
Fecha de publicación: 02/2010
Editorial: IOP Publishing
Revista: Journal of Geophysics and Engineering
ISSN: 1742-2132
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Meteorología y Ciencias Atmosféricas

Resumen

The focus of this study is to analyse the reliability of using small-loop frequency-domain electromagnetic induction systems for characterizing buried storage tanks and pipes at industrial plants. As examples, we selected two areas of a chemical plant, one located outdoors and the other inside a room of reduced dimensions. We collected data employing different system orientations and acquisition directions, in order to compare the influence of environmental noise and neighbouring structures on each case. We found that the presence of a metallic gate or other metallic stuff in a neighbouring wall introduces strong distortions in the responses obtained near these objects. The responses decrease when the coils are coplanar with the wall and increase when they are perpendicular to it. Noise levels were higher for the data acquired indoors, but even in this case, we could enhance the signal-to-noise ratios up to very acceptable values by applying a novel spatial filtering technique. This improved the visualization of the anomalies associated with the targets. Finally, we generated pseudo 3D electrical models of the subsoil, by combining the results of the 1D inversions of the filtered data corresponding to the configuration that best evidenced the structures buried on each sector. In both areas, we obtained quite good approximate characterizations of the geometry, conductivity and depth of the detected tanks and pipes, as was later confirmed during remediation works. Remarkably, the model obtained for the area located indoors had enough resolution as to define the existence of two separate, adjacent tanks. © 2010 Nanjing Institute of Geophysical Prospecting.
Palabras clave: Electromagnetic Induction , Small-Loop , Industrial Plants , Spatial Filtering , Inversion
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 3.545Mb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/59101
DOI: http://dx.doi.org/10.1088/1742-2132/7/1/008
Colecciones
Articulos(IFIBA)
Articulos de INST.DE FISICA DE BUENOS AIRES
Citación
Martinelli, Hilda Patricia; Osella, Ana Maria; Small-loop electromagnetic induction for environmental studies at industrial plants; IOP Publishing; Journal of Geophysics and Engineering; 7; 1; 2-2010; 91-104
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES