Mostrar el registro sencillo del ítem

dc.contributor.author
O´donell, Beatriz Maria  
dc.contributor.author
Colombo, Elisa Margarita  
dc.date.available
2018-09-03T15:09:13Z  
dc.date.issued
2016-04  
dc.identifier.citation
O´donell, Beatriz Maria; Colombo, Elisa Margarita; The Appropriateness of Contrast Metric for Reaction Times; Pion Ltd; Perception; 45; 8; 4-2016; 931-945  
dc.identifier.issn
0301-0066  
dc.identifier.uri
http://hdl.handle.net/11336/58055  
dc.description.abstract
We analyzed different contrast metrics to scale the stimulus strength for suprathreshold reaction times (RTs) when it is modulated along an achromatic channel (L þ M) and both chromatic channels L/M and S/(L þ M) considering increments and decrements along these axes. RTs were examined as a function of the Weber luminance contrast; spatial luminance ratio (SRL) and, in terms of threshold units. The results show that when there is only luminance decreasing or increasing, RTs cluster around a single RT/luminance contrast function regardless the stimulus sign and our results indicate that both SRL, Weber luminance contrast or threshold units, equate RT values. While, if the stimulus is modulated along an isoluminant plane, the appropriate contrast is Weber (RMS) or SRL for stimuli modulated along L/M axis and for stimuli modulated along S/ L þ M, showing an asymmetry between S-cone decrements and increments in L/M cone pathway. Threshold units are not appropriate, showing inconsistencies: The stimulus with chromatic direction equal to 90º appears as the most informative with a maximum gain. Even more so, the shared contrast gain grows as the size of the stimulus decreases.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Pion Ltd  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
Reaction Time  
dc.subject
Contrast  
dc.subject
Threshold Unit  
dc.subject
Suprathreshold  
dc.subject
Metric  
dc.subject.classification
Otras Ciencias Físicas  
dc.subject.classification
Ciencias Físicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
The Appropriateness of Contrast Metric for Reaction Times  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2018-08-27T19:19:09Z  
dc.journal.volume
45  
dc.journal.number
8  
dc.journal.pagination
931-945  
dc.journal.pais
Reino Unido  
dc.journal.ciudad
Londres  
dc.description.fil
Fil: O´donell, Beatriz Maria. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto de Investigación en Luz, Ambiente y Visión. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Instituto de Investigación en Luz, Ambiente y Visión; Argentina. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Luminotecnia, Luz y Visión; Argentina  
dc.description.fil
Fil: Colombo, Elisa Margarita. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto de Investigación en Luz, Ambiente y Visión. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Instituto de Investigación en Luz, Ambiente y Visión; Argentina. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Luminotecnia, Luz y Visión; Argentina  
dc.journal.title
Perception  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1177%2F0301006616643651  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://journals.sagepub.com/doi/full/10.1177/0301006616643651