dc.identifier.citation
Maratta Martínez, Sergio Ariel; Acosta, Mariano; Martinez, Luis Dante; Pacheco, Pablo Hugo; Gil, Raul Andres; Ultratrace arsenic determination through hydride trapping on oxidized multiwall carbon nanotubes coupled to electrothermal atomic absorption spectrometry; Royal Society of Chemistry; Journal of Analytical Atomic Spectrometry; 28; 6; 22-3-2013; 916-922
dc.identifier.issn
0267-9477
dc.identifier.uri
http://hdl.handle.net/11336/5792
dc.description.abstract
Arsenic determination in natural waters is an issue of current research. This article reports a novel hydride generation (HG) approach developed for As determination with electrothermal atomic absorption spectrometry (ETAAS) detection. The HG process was interfaced with ETAAS through hydride trapping onto a carbon nanotubes microcolumn. To this end a homemade gas-liquid separator was used, allowing arsine formation and its flow throughout the CNT microcolumn. The retention process involved thus a solid phase extraction from the gas phase to the solid support. Once arsine generation was completed, the elution was carried out with nitric acid directly onto the dosing hole of the graphite furnace. Outstanding sensitivity with detection limit of 1 ng L-1, quantification limit of 5 ng L-1 and the characteristic mass, 5.8 ± 0.4 pg could be achieved. A satisfactory correlation between concentration of As and absorbance (R = 0.9993) from the limit of quantification up to 500 ng L-1, with a relative standard deviation of 6.3% were obtained. A sensitive enhancement factor of 38 was reached when 2 mL of sample were processed and 50 μL of HNO3 were used as eluent. The system was successfully applied to the analysis of a standard reference material, QC LL2 metals in natural waters. In addition tap water analysis provided an As concentration of 0.29±0.03 μg L-1.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Royal Society of Chemistry
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
Arsenic
dc.subject
Hydride Trapping
dc.subject
Oxidized Multiwall Carbon Nanotubes
dc.subject
Electrotermal Atomic Absorption Spectrometry
dc.subject.classification
Química Analítica
dc.subject.classification
Ciencias Químicas
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS
dc.title
Ultratrace arsenic determination through hydride trapping on oxidized multiwall carbon nanotubes coupled to electrothermal atomic absorption spectrometry
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2016-05-16T20:14:33Z
dc.journal.volume
28
dc.journal.number
6
dc.journal.pagination
916-922
dc.journal.pais
Reino Unido
dc.journal.ciudad
Cambridge
dc.description.fil
Fil: Maratta Martínez, Sergio Ariel. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico San Luis. Instituto de Química de San Luis; Argentina
dc.description.fil
Fil: Acosta, Mariano. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico San Luis. Instituto de Química de San Luis; Argentina
dc.description.fil
Fil: Martinez, Luis Dante. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico San Luis. Instituto de Química de San Luis; Argentina
dc.description.fil
Fil: Pacheco, Pablo Hugo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico San Luis. Instituto de Química de San Luis; Argentina
dc.description.fil
Fil: Gil, Raul Andres. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico San Luis. Instituto de Química de San Luis; Argentina
dc.journal.title
Journal of Analytical Atomic Spectrometry
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://pubs.rsc.org/en/content/articlelanding/2013/ja/c3ja30385c
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1039/C3JA30385C
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/10.1039/C3JA30385C