dc.identifier.citation
Campbell, Graeme M; Peña, Jaime A; Giravent, Sarah; Thomsen, Felix Sebastian Leo; Damm, Timo; et al.; Assessment of Bone Fragility in Patients With Multiple Myeloma Using QCT-Based Finite Element Modeling; American Society for Bone and Mineral Research; Journal of Bone and Mineral Research; 32; 1; 1-2017; 151-156
dc.identifier.issn
0884-0431
dc.identifier.uri
http://hdl.handle.net/11336/55621
dc.description.abstract
Multiple myeloma (MM) is a malignant plasma cell disease associated with severe bone destruction. Surgical intervention is often required to prevent vertebral body collapse and resulting neurological complications; however, its necessity is determined by measuring lesion size or number, without considering bone biomechanics. Finite element (FE) modeling, which simulates the physiological loading, may improve the prediction of fragility. To test this, we developed a quantitative computed tomography (QCT)-based FE model of the vertebra and applied it to a dataset of MM patients with and without prevalent fracture. FE models were generated from vertebral QCT scans of the T12 (T11 if T12 was fractured) of 104 MM patients, 45 with fracture and 59 without, using a low-dose scan protocol (1.5 mm slice thickness, 4.0 to 6.5 mSv effective dose). A calibration phantom enabled the conversion of the CT Hounsfield units to FE material properties. Compressive loading of the vertebral body was simulated and the stiffness, yield load, and work to yield determined. To compare the parameters between fracture and nonfracture groups, t tests were used, and standardized odds ratios (sOR, normalized to standard deviation) and 95% confidence intervals were calculated. FE parameters were compared to mineral and structural parameters using linear regression. Patients with fracture showed lower vertebral stiffness (–15.2%; p = 0.010; sOR = 1.73; 95% CI, 1.11 to 2.70), yield force (–21.5%; p = 0.002; sOR = 2.09; 95% CI, 1.27 to 3.43), and work to yield (–27.4%; p = 0.001; sOR = 2.28; 95% CI, 1.33 to 3.92) compared to nonfracture patients. All parameters correlated significantly with vBMD (stiffness: R2 = 0.57, yield force: R2 = 0.59, work to yield: R2 = 0.50, p < 0.001), BV/TV (stiffness: R2 = 0.56, yield force: R2 = 0.58, work to yield: R2 = 0.49, p < 0.001), and Tb.Sp (stiffness: R2 = 0.51, yield force: R2 = 0.53, work to yield: R2 = 0.45, p < 0.001). FE modeling identified MM patients with compromised mechanical integrity of the vertebra. Higher sOR values were obtained for the biomechanical compared to structural or mineral measures, suggesting that FE modeling improves fragility assessment in these patients.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
American Society for Bone and Mineral Research
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
Biomechanics
dc.subject
Bone Qct
dc.subject
Primary Tumors of Bone And Cartilage
dc.subject
Radiology
dc.subject.classification
Inmunología
dc.subject.classification
Medicina Básica
dc.subject.classification
CIENCIAS MÉDICAS Y DE LA SALUD
dc.title
Assessment of Bone Fragility in Patients With Multiple Myeloma Using QCT-Based Finite Element Modeling
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2018-07-23T18:12:22Z
dc.journal.volume
32
dc.journal.number
1
dc.journal.pagination
151-156
dc.journal.pais
Estados Unidos
dc.journal.ciudad
Washington DC
dc.description.fil
Fil: Campbell, Graeme M. University Hospital Schleswig‐HolsteinKiel; Alemania. Universitat Hamburg; Alemania
dc.description.fil
Fil: Peña, Jaime A. University Hospital Schleswig‐HolsteinKiel; Alemania
dc.description.fil
Fil: Giravent, Sarah. University Hospital Schleswig‐HolsteinKiel; Alemania
dc.description.fil
Fil: Thomsen, Felix Sebastian Leo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Investigaciones en Ingeniería Eléctrica ; Argentina
dc.description.fil
Fil: Damm, Timo. University Hospital Schleswig‐HolsteinKiel; Alemania
dc.description.fil
Fil: Glüer, Claus C.. University Hospital Schleswig‐HolsteinKiel; Alemania
dc.description.fil
Fil: Borggrefe, Jan. University Hospital Schleswig‐HolsteinKiel; Alemania. Universitat zu Köln; Alemania
dc.journal.title
Journal of Bone and Mineral Research
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1002/jbmr.2924
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://onlinelibrary.wiley.com/doi/abs/10.1002/jbmr.2924