Artículo
Decrease in Cytotoxicity of Copper-Based Intrauterine Devices (IUD) Pretreated with 6-Mercaptopurine and Pterin as Biocompatible Corrosion Inhibitors
Alvarez, Florencia
; Grillo, Claudia Alejandra
; Schilardi, Patricia Laura
; Rubert, Aldo Alberto
; Benitez, Guillermo Alfredo
; Lorente, Carolina
; Fernandez Lorenzo, Monica Alicia
Fecha de publicación:
02/2013
Editorial:
American Chemical Society
Revista:
Acs Applied Materials & Interfaces
ISSN:
1944-8244
Idioma:
Inglés
Tipo de recurso:
Artículo publicado
Clasificación temática:
Resumen
The copper intrauterine device (IUD) based its contraceptive action on the release of cupric ions from a copper wire. Immediately after the insertion, a burst release of copper ions occurs, which may be associated to a variety of side effects. 6-Mercaptopurine (6-MP) and pterin (PT) have been proposed as corrosion inhibitors to reduce this harmful release. Pretreatments with 1x10-4 M 6-MP and 1x10-4 M PT solutions with 1h and 3h immersion times were tested. Conventional electrochemical techniques, EDX and XPS analysis, and cytotoxicity assays with HeLa cell line were employed to investigate the corrosion behavior and biocompatibility of copper with and without treatments. Results showed that copper samples treated with PT and 6-MP solutions for 3 and 1 h, respectively, are more biocompatible than those without treatment. Besides, the treatment reduces the burst release effect of copper in simulated uterine solutions during the first week after the insertion. It was concluded that PT and 6-MP treatments are promising strategies able to reduce the side effects related to the "burst release" of copper-based IUD without altering the contraceptive action.
Palabras clave:
Intrauterine Device
,
Copper
,
Copper Ions
,
Pterin
Archivos asociados
Licencia
Identificadores
Colecciones
Articulos(CCT - LA PLATA)
Articulos de CTRO.CIENTIFICO TECNOL.CONICET - LA PLATA
Articulos de CTRO.CIENTIFICO TECNOL.CONICET - LA PLATA
Articulos(INIFTA)
Articulos de INST.DE INV.FISICOQUIMICAS TEORICAS Y APLIC.
Articulos de INST.DE INV.FISICOQUIMICAS TEORICAS Y APLIC.
Articulos(SEDE CENTRAL)
Articulos de SEDE CENTRAL
Articulos de SEDE CENTRAL
Citación
Alvarez, Florencia; Grillo, Claudia Alejandra; Schilardi, Patricia Laura; Rubert, Aldo Alberto; Benitez, Guillermo Alfredo; et al.; Decrease in Cytotoxicity of Copper-Based Intrauterine Devices (IUD) Pretreated with 6-Mercaptopurine and Pterin as Biocompatible Corrosion Inhibitors; American Chemical Society; Acs Applied Materials & Interfaces; 5; 2; 2-2013; 249-255
Compartir
Altmétricas