Mostrar el registro sencillo del ítem

dc.contributor.author
Primo, Emiliano Nicolás  
dc.contributor.author
Gutierrez, Fabiana Andrea  
dc.contributor.author
Rubianes, María Dolores  
dc.contributor.author
Rivas, Gustavo Adolfo  
dc.date.available
2018-06-05T19:56:56Z  
dc.date.issued
2015-11-10  
dc.identifier.citation
Primo, Emiliano Nicolás; Gutierrez, Fabiana Andrea; Rubianes, María Dolores; Rivas, Gustavo Adolfo; Bamboo-like multiwalled carbon nanotubes dispersed in double stranded calf-thymus DNA as a new analytical platform for building layer-by-layer based biosensors; Pergamon-Elsevier Science Ltd; Electrochimica Acta; 182; 10-11-2015; 391-397  
dc.identifier.issn
0013-4686  
dc.identifier.uri
http://hdl.handle.net/11336/47381  
dc.description.abstract
This work reports the successful application of bamboo-like multiwalled carbon nanotubes (bCNT) non-covalently functionalized with calf-thymus double stranded DNA (dsDNA) as a robust platform (bCNT-dsDNA) to build electrochemical biosensors. The “model system” proposed here as a proof of concept was an enzymatic biosensor devoted to glucose quantification obtained by layer-by-layer self-assemby of polydiallyldimethylammonium (PDDA) and glucose oxidase (GOx) at glassy carbon electrodes (GCE) modified with bCNT-dsDNA (GCE/bCNT-dsDNA/(PDDA/GOx)n). The influence of GOx and PDDA assembling conditions and the effect of the number of PDDA/GOx bilayers (n) on the performance of the resulting biosensor is critically discussed. The supramolecular architecture was characterized by electrochemical impedance spectroscopy from the charge transfer resistance of quinone/hydroquinone and potassium ferrocyanide/potassium ferricyanide; by cyclic voltammetry from the surface concentration of GOx using ferrocene methanol as enzyme regenerator; by amperometry from the response of the enzymatically generated hydrogen peroxide; and by surface plasmon resonance from the changes in the plasmon resonance angle. The analytical parameters obtained with GCE/bCNT-dsDNA/(PDDA/GOx)3 for the amperometric quantification of glucose at 0.700 V were: sensitivity of (265 ± 7) μA mM−1 cm−2, linear range between 0.25 and 2.50 × 10−3 M, detection limit of 50 μM, repeatability of 3.6% (n = 10), and negligible interference from maltose, galactose, fructose and manose. The biosensor was successfully used for the sensitive quantification of glucose in beverages and a medicine sample.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Pergamon-Elsevier Science Ltd  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
Carbon Nanotubes Functionalization  
dc.subject
Calf-Thymus Double Stranded  
dc.subject
Glucose Oxidase  
dc.subject
Layer-By-Layer Biosensors  
dc.subject
Self-Assembly  
dc.subject
Electrochemical Glucose Biosensor  
dc.subject
Bamboo-Like Multiwalled Carbon Nanotubes  
dc.subject.classification
Otras Ciencias Químicas  
dc.subject.classification
Ciencias Químicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Bamboo-like multiwalled carbon nanotubes dispersed in double stranded calf-thymus DNA as a new analytical platform for building layer-by-layer based biosensors  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2018-05-07T18:04:28Z  
dc.journal.volume
182  
dc.journal.pagination
391-397  
dc.journal.pais
Países Bajos  
dc.journal.ciudad
Amsterdam  
dc.description.fil
Fil: Primo, Emiliano Nicolás. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina  
dc.description.fil
Fil: Gutierrez, Fabiana Andrea. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina  
dc.description.fil
Fil: Rubianes, María Dolores. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina  
dc.description.fil
Fil: Rivas, Gustavo Adolfo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina  
dc.journal.title
Electrochimica Acta  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S0013468615304400  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.electacta.2015.09.028