Mostrar el registro sencillo del ítem
dc.contributor.author
Torres, Dimas Ignacio
dc.contributor.author
Miranda, Maria Victoria
dc.contributor.author
Campodallorto, Viviana
dc.date.available
2018-06-04T19:58:22Z
dc.date.issued
2017-02
dc.identifier.citation
Torres, Dimas Ignacio; Miranda, Maria Victoria; Campodallorto, Viviana; One-pot preparation of SBP-PANI-PAA-ethylene glycol diglycidyl ether sensor for electrochemical detection of H 2 O 2; Elsevier Science Sa; Sensors and Actuators B: Chemical; 239; 2-2017; 1016-1025
dc.identifier.issn
0925-4005
dc.identifier.uri
http://hdl.handle.net/11336/47206
dc.description.abstract
Soybean seed coat peroxidase (SBP) was used in combination with aniline (ANI), acrylic acid (AA), ethylene glycol diglycidyl ether (EGDE) and H2O2, to prepare a biosensor in one-pot synthesis strategy. SBP catalyzed the chemical polymerization of ANI initiated by H2O2, to give the conductive polymer (PANI) in acidic medium where acrylate acted as dopant. Further reactions between free radicals, AA and the diepoxy EGDE determined the entrapment of the SBP together with PANI in a hydrogel on the electrode surface, becoming wired for the amperometric detection of H2O2 at neutral pH and −100 mV vs Ag/AgCl. On the other hand, the absence of AA and EGDE in the reaction mixture led to an unstable sensor modifier and an erratic response to H2O2. The apparent Km for immobilized SBP in the flow system was 0.0763 mM, lower than the parameter for the free enzyme at pH 7.0. Quantitative analysis of H2O2 was carried out in a flow injection system (FIA); the calibration plot was linear in the range of 5.0–50 μM, with a limit of detection of 2.2 μM. A dental bleaching sample was successfully analyzed and the catalase test results demonstrated the specificity of the response.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Elsevier Science Sa
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
dc.subject
Epoxy
dc.subject
Hydrogen Peroxide
dc.subject
Poly(Acrylic Acid)
dc.subject
Polyaniline
dc.subject
Soybean Seed Coat Peroxidase
dc.subject.classification
Otras Ciencias Químicas
dc.subject.classification
Ciencias Químicas
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS
dc.title
One-pot preparation of SBP-PANI-PAA-ethylene glycol diglycidyl ether sensor for electrochemical detection of H 2 O 2
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2018-06-04T17:31:36Z
dc.journal.volume
239
dc.journal.pagination
1016-1025
dc.journal.pais
Países Bajos
dc.journal.ciudad
Amsterdam
dc.description.fil
Fil: Torres, Dimas Ignacio. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Houssay. Instituto de Química y Físico-Química Biológicas "Prof. Alejandro C. Paladini". Universidad de Buenos Aires. Facultad de Farmacia y Bioquímica. Instituto de Química y Físico-Química Biológicas; Argentina
dc.description.fil
Fil: Miranda, Maria Victoria. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Houssay. Instituto de Nanobiotecnología. Universidad de Buenos Aires. Facultad de Farmacia y Bioquímica. Instituto de Nanobiotecnología; Argentina
dc.description.fil
Fil: Campodallorto, Viviana. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Houssay. Instituto de Química y Físico-Química Biológicas "Prof. Alejandro C. Paladini". Universidad de Buenos Aires. Facultad de Farmacia y Bioquímica. Instituto de Química y Físico-Química Biológicas; Argentina
dc.journal.title
Sensors and Actuators B: Chemical
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/https://dx.doi.org/10.1016/j.snb.2016.08.110
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0925400516313429
Archivos asociados