Multiclass compatible sample preparation for UHPLC-MS/MS determination of aflatoxin M1 in raw milk

Michlig, NicolásIcon ; Repetti, María Rosa; Chiericatti, Carolina; García, Silvia R.; Gaggiotti, Mónica; Basilico, Juan Carlos; Beldomenico, Horacio Ramon
Fecha de publicación: 10/2015
Editorial: Springer
Revista: Chromatographia
ISSN: 0009-5893
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Otras Ciencias Químicas

Resumen

A sample preparation method for aflatoxin M1 (AFM1) determination in raw milk was optimized following the quick, easy, cheap, effective, rugged and safe (QuEChERS) strategy, as an alternative to the classic immunoaffinity column clean-up (IAC). The method was adapted to address the complexity of the milk matrix, and to be suitable for final determination by ultra-high performance liquid chromatography coupled to tandem mass spectrometry (UHPLC–MS/MS). This approach proved also to be compatible with the simultaneous extraction of pesticide residues and other contaminants (mycotoxins). Regarding AFM1, satisfactory linearity was achieved and appropriate sensitivity was maintained, using matrix-matched calibration to compensate for the heavy ion suppression. The accuracy and precision, which were determined through recovery studies, were 70–95 %, with the relative standard deviation below 15 % in all of the cases. The limit of detection (LOD, 0.002 μg L−1) and limit of quantification (0.007 μg L−1) are compatible with current worldwide regulations (maximum levels of 0.5 and 0.05 μg L−1). The procedure was applied to samples that were naturally contaminated with a range of AFM1 at LOQ–0.187 μg L−1, with comparable results to IAC clean-up, which was employed as a reference method. Therefore, AFM1 determination in raw milk by UHPLC–MS/MS detection through the present QuEChERS extraction constitutes a reliable alternative to IAC clean-up and exhibits advantages related to cost, accessibility of materials and simplicity of operation.
Palabras clave: Lc-Ms/Ms , Quechers , Mycotoxins , Milk , Pesticides
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 1.638Mb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/45964
DOI: http://dx.doi.org/10.1007/s10337-015-2972-1
URL: https://link.springer.com/article/10.1007%2Fs10337-015-2972-1
Colecciones
Articulos(CCT - SANTA FE)
Articulos de CTRO.CIENTIFICO TECNOL.CONICET - SANTA FE
Citación
Michlig, Nicolás; Repetti, María Rosa; Chiericatti, Carolina; García, Silvia R.; Gaggiotti, Mónica; et al.; Multiclass compatible sample preparation for UHPLC-MS/MS determination of aflatoxin M1 in raw milk; Springer; Chromatographia; 79; 17-18; 10-2015; 1091-1100
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES