Mostrar el registro sencillo del ítem
dc.contributor.author
Milano, Federico Edgardo
dc.contributor.author
Ritacco, Lucas
dc.contributor.author
Farfalli, Germán Luis
dc.contributor.author
Bahamonde, Luis Alberto
dc.contributor.author
Aponte Tinao, Luis Alberto
dc.contributor.author
Risk, Marcelo
dc.date.available
2018-04-10T20:02:48Z
dc.date.issued
2015-05
dc.identifier.citation
Milano, Federico Edgardo; Ritacco, Lucas; Farfalli, Germán Luis; Bahamonde, Luis Alberto; Aponte Tinao, Luis Alberto; et al.; Transfer accuracy and precision scoring in planar bone cutting validated with ex vivo data; John Wiley & Sons Inc; Journal Of Orthopaedic Research; 33; 5; 5-2015; 699-704
dc.identifier.issn
0736-0266
dc.identifier.uri
http://hdl.handle.net/11336/41590
dc.description.abstract
The use of interactive surgical scenarios for virtual preoperative planning of osteotomies has increased in the last 5 years.As it has been reported by several authors, this technology has been used in tumor resection osteotomies, knee osteotomies, and spine surgery with good results. A digital three-dimensional preoperative plan makes possible to quantitatively evaluate the transfer processfrom the virtual plan to the anatomy of the patient. We introduce an exact definition of accuracy and precision of this transfer process for planar bone cutting. We present a method to compute these properties from ex vivo data. We also propose a clinical score to assess the goodness of a cut. A computer simulation is used to characterize the definitions and the data generated by the measurement method. The definitions and method are evaluated in 17 ex vivo planar cuts of tumor resection osteotomies. The results show that the proposed method and definitions are highly correlated with a previous definition of accuracy based in ISO 1101. The score is also evaluated by showing that it distinguishes among different transfer techniques based in its distribution location and shape. The introduced definitions produce acceptable results in cases where the ISO-based definition produce counter intuitive results.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
John Wiley & Sons Inc
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
Osteotomy
dc.subject
Accuracy
dc.subject
Precision
dc.subject
Clinical Score
dc.subject.classification
Medicina Critica y de Emergencia
dc.subject.classification
Medicina Clínica
dc.subject.classification
CIENCIAS MÉDICAS Y DE LA SALUD
dc.title
Transfer accuracy and precision scoring in planar bone cutting validated with ex vivo data
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2018-04-10T17:50:45Z
dc.journal.volume
33
dc.journal.number
5
dc.journal.pagination
699-704
dc.journal.pais
Estados Unidos
dc.journal.ciudad
Nueva York
dc.description.fil
Fil: Milano, Federico Edgardo. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Instituto Tecnológico de Buenos Aires; Argentina
dc.description.fil
Fil: Ritacco, Lucas. Hospital Italiano; Argentina
dc.description.fil
Fil: Farfalli, Germán Luis. Hospital Italiano; Argentina
dc.description.fil
Fil: Bahamonde, Luis Alberto. Universidad de Chile; Chile
dc.description.fil
Fil: Aponte Tinao, Luis Alberto. Hospital Italiano; Argentina
dc.description.fil
Fil: Risk, Marcelo. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Instituto Tecnológico de Buenos Aires; Argentina
dc.journal.title
Journal Of Orthopaedic Research
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://onlinelibrary.wiley.com/doi/abs/10.1002/jor.22813
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1002/jor.22813
Archivos asociados