Mostrar el registro sencillo del ítem
dc.contributor.author
Rincon Soler, Anderson Ivan
dc.contributor.author
Silva, Luiz Eduardo Virgilio
dc.contributor.author
Fazan, Rubens
dc.contributor.author
Murta Junior, Luiz Otavio
dc.date.available
2018-03-12T21:35:23Z
dc.date.issued
2017-09
dc.identifier.citation
Rincon Soler, Anderson Ivan; Silva, Luiz Eduardo Virgilio; Fazan, Rubens; Murta Junior, Luiz Otavio; The impact of artifact correction methods of RR series on heart rate variability parameters; American Physiological Society; Journal Of Applied Physiology; 9-2017; 1-23
dc.identifier.issn
8750-7587
dc.identifier.uri
http://hdl.handle.net/11336/38640
dc.description.abstract
Heart rate variability (HRV) analysis is widely used to investigate the autonomic regulation of the cardiovascular system. HRV is often analyzed using RR time series, which can be affected by different types of artifacts. Although there are several artifact correction methods, there is no study that compares their performances in actual experimental contexts. This work aimed to evaluate the impact of different artifact correction methods on several HRV parameters. Initially, 36 ECG recordings of control rats or rats with heart failure or hypertension were analyzed to characterize artifacts occurrence rates and distributions, in order to be mimicked in simulations. After a rigorous analysis, only sixteen recordings (N=16) with artifact-free segments of at least 10.000 beats were selected. Then, RR interval losses were simulated in the artifact-free (reference) time series according to real observations. Correction methods applied to simulated series were deletion (DEL), linear interpolation (LI), cubic spline interpolation (CI), modified moving average window (mMAW) and nonlinear predictive interpolation (NPI). Linear (time- and frequency-domain) and nonlinear HRV parameters were calculated from corrupted-corrected time series, as well as for reference series to evaluate the accuracy of each correction method. Results show that NPI provides the overall best performance. However, several correction approaches, for example, the simple deletion procedure, can provide good performance in some situations, depending on the HRV parameters under consideration.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
American Physiological Society
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
Heart Rate Variability
dc.subject
Artifact Correction
dc.subject
Time Domain
dc.subject
Frequency Domain
dc.subject
Nonlinear Analysis
dc.subject.classification
Fisiología
dc.subject.classification
Medicina Básica
dc.subject.classification
CIENCIAS MÉDICAS Y DE LA SALUD
dc.title
The impact of artifact correction methods of RR series on heart rate variability parameters
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2018-03-12T19:31:56Z
dc.journal.pagination
1-23
dc.journal.pais
Estados Unidos
dc.description.fil
Fil: Rincon Soler, Anderson Ivan. Universidade de Sao Paulo; Brasil. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
dc.description.fil
Fil: Silva, Luiz Eduardo Virgilio. Universidade de Sao Paulo; Brasil
dc.description.fil
Fil: Fazan, Rubens. Universidade de Sao Paulo; Brasil
dc.description.fil
Fil: Murta Junior, Luiz Otavio. Universidade de Sao Paulo; Brasil
dc.journal.title
Journal Of Applied Physiology
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1152/japplphysiol.00927.2016
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.physiology.org/doi/10.1152/japplphysiol.00927.2016
Archivos asociados