Mostrar el registro sencillo del ítem

dc.contributor.author
Rincon Soler, Anderson Ivan  
dc.contributor.author
Silva, Luiz Eduardo Virgilio  
dc.contributor.author
Fazan, Rubens  
dc.contributor.author
Murta Junior, Luiz Otavio  
dc.date.available
2018-03-12T21:35:23Z  
dc.date.issued
2017-09  
dc.identifier.citation
Rincon Soler, Anderson Ivan; Silva, Luiz Eduardo Virgilio; Fazan, Rubens; Murta Junior, Luiz Otavio; The impact of artifact correction methods of RR series on heart rate variability parameters; American Physiological Society; Journal Of Applied Physiology; 9-2017; 1-23  
dc.identifier.issn
8750-7587  
dc.identifier.uri
http://hdl.handle.net/11336/38640  
dc.description.abstract
Heart rate variability (HRV) analysis is widely used to investigate the autonomic regulation of the cardiovascular system. HRV is often analyzed using RR time series, which can be affected by different types of artifacts. Although there are several artifact correction methods, there is no study that compares their performances in actual experimental contexts. This work aimed to evaluate the impact of different artifact correction methods on several HRV parameters. Initially, 36 ECG recordings of control rats or rats with heart failure or hypertension were analyzed to characterize artifacts occurrence rates and distributions, in order to be mimicked in simulations. After a rigorous analysis, only sixteen recordings (N=16) with artifact-free segments of at least 10.000 beats were selected. Then, RR interval losses were simulated in the artifact-free (reference) time series according to real observations. Correction methods applied to simulated series were deletion (DEL), linear interpolation (LI), cubic spline interpolation (CI), modified moving average window (mMAW) and nonlinear predictive interpolation (NPI). Linear (time- and frequency-domain) and nonlinear HRV parameters were calculated from corrupted-corrected time series, as well as for reference series to evaluate the accuracy of each correction method. Results show that NPI provides the overall best performance. However, several correction approaches, for example, the simple deletion procedure, can provide good performance in some situations, depending on the HRV parameters under consideration.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
American Physiological Society  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
Heart Rate Variability  
dc.subject
Artifact Correction  
dc.subject
Time Domain  
dc.subject
Frequency Domain  
dc.subject
Nonlinear Analysis  
dc.subject.classification
Fisiología  
dc.subject.classification
Medicina Básica  
dc.subject.classification
CIENCIAS MÉDICAS Y DE LA SALUD  
dc.title
The impact of artifact correction methods of RR series on heart rate variability parameters  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2018-03-12T19:31:56Z  
dc.journal.pagination
1-23  
dc.journal.pais
Estados Unidos  
dc.description.fil
Fil: Rincon Soler, Anderson Ivan. Universidade de Sao Paulo; Brasil. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina  
dc.description.fil
Fil: Silva, Luiz Eduardo Virgilio. Universidade de Sao Paulo; Brasil  
dc.description.fil
Fil: Fazan, Rubens. Universidade de Sao Paulo; Brasil  
dc.description.fil
Fil: Murta Junior, Luiz Otavio. Universidade de Sao Paulo; Brasil  
dc.journal.title
Journal Of Applied Physiology  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1152/japplphysiol.00927.2016  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.physiology.org/doi/10.1152/japplphysiol.00927.2016