dc.description.abstract
The aim of this study was to evaluate the clinical behavior of two conventional glass ionomers used for pit and fissure sealing in terms of retention, marginal adaptation, caries recurrence and cracking. Eighty-three fully erupted first permanent molars were sealed, in a group of children aged 5 to 8 years. A doubleblind, single operator, paired design was used. Materials applied were Fuji IX and VII. Retention (R), presence of caries (PC), marginal discoloration (MD), marginal adaptation (MA) and cracking (C) were evaluated at 6 and 12 months using Ryge’s criteria. Data registered 6 months after treatment were: Fuji IX: R: Alpha 37, Bravo 2, Charlie: 4; PC: Alpha 43, Bravo: 0; MA: Alpha 38, Bravo: 1; MD: Alpha 39, Bravo: 0, Charlie: 0; C: Alpha 39, Bravo: 0. Fuji VII: R: Alpha 29, Bravo 4, Charlie: 7; PC: Alpha 40, Bravo: 0; MA: Alpha: 34, Bravo: 0; MD: Alpha: 34, Bravo: 0; Charlie: 0; C: Alpha 33, Bravo: 0. Results after one year were: Fuji IX: R: Alpha 33, Bravo: 3, Charlie: 9; PC: Alpha 44, Bravo: 1; MA: Alpha 33, Bravo: 1; MD: Alpha: 34, Bravo: 0, Charlie: 0; C: Alpha: 34, Bravo: 0. Fuji VII: R: Alpha 22, Bravo 4, Charlie: 13, PC: Alpha 40, Bravo: 0; MA: Alpha 23, Bravo: 1; MD: Alpha 23, Bravo: 1, Charlie: 0; C: Alpha 23, Bravo: 1. Statistical analysis using Fisher test showed no significant difference (p>0.05) for R, and MA. For PC, MD and C, values are not reported because both materials showed the same results. The second control showed no significant difference (p>0.05) for R, MA, PC, MD and C. Results suggest no difference between Fuji IX and Fuji VII as sealants in fully erupted permanent molars.
dc.description.abstract
El objetivo de este trabajo fue evaluar el comportamiento clinico de dos ionomeros vitreos convencionales aplicados como selladores de fosas y fisuras. Se evaluo la retencion, decoloracion y adaptacion marginal, incidencia de caries y agrietamiento. Se sellaron ochenta y tres primeros molares totalmente erupcionados en un grupo de ninos de 5 a 8 anos. Se llevo a cabo un diseno de doble ciego, unico operador y apareado. Los materiales aplicados fueron Fuji IX y VII. Luego de 6 y 12 meses se recitaron los ninos y se evaluo: Retencion (R), presencia de caries (PC), decoloracion marginal (MD) y agrietamiento (C). La evaluacion se realizo utilizando los criterios de Ryge. Los datos registrados al cabo de 6 meses fueron: Fuji IX: R: Alpha 37, Bravo 2, Charlie: 4; PC: Alpha 43, Bravo: 0; MA: Alpha 38, Bravo: 1; MD: Alpha 39, Bravo: 0, Charlie: 0; C: Alpha 39, Bravo: 0. Fuji VII: R: Alpha 29, Bravo 4, Charlie: 7; PC: Alpha 40, Bravo: 0; MA: Alpha: 34, Bravo: 0; MD: Alpha: 34, Bravo: 0; Charlie: 0; C: Alpha 33, Bravo: 0. A los 12 meses: Fuji IX: R: Alpha 33, Bravo: 3, Charlie: 9; PC: Alpha 44, Bravo: 1; MA: Alpha 33, Bravo: 1; MD: Alpha: 34, Bravo: 0, Charlie: 0; C: Alpha: 34, Bravo: 0. Fuji VII: R: Alpha 22, Bravo 4, Charlie: 13, PC: Alpha 40, Bravo: 0; MA: Alpha 23, Bravo: 1; MD: Alpha 23, Bravo: 1, Charlie: 0; C: Alpha 23, Bravo: 1. La evaluacion estadistica por medio de la prueba de Fisher no mostro diferencias significativas entre los materiales (p>0.05) para R y MA. En PC, MD y C, el valor de p no se indica ya que los resultados fueron identicos. El segundo control no mostro diferencias significativas (p>0.05) para R, MA, PC, MD y C. Los resultados sugieren que no existiria diferencia en la aplicacion de Fuji IX y Fuji VII como selladores de fosas y fisuras en molares totalmente erupcionados.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Facultad de Odontología Universidad de Buenos Aires
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
Ionomero Vitreo
dc.subject
Selladores De Fosas y Fisuras
dc.subject.classification
Otras Ciencias de la Salud
dc.subject.classification
Ciencias de la Salud
dc.subject.classification
CIENCIAS MÉDICAS Y DE LA SALUD
dc.title
Clinical evaluation of glass ionomer for pit and fissure sealing of fully erupted molars
dc.title
Evaluación clínica de cementos de ionómero vítreo aplicados como selladores de fosas y fisuras
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2018-03-02T14:58:02Z
dc.journal.volume
23
dc.journal.number
1
dc.journal.pagination
3-7
dc.journal.pais
Argentina
dc.journal.ciudad
Buenos Aires
dc.description.fil
Fil: Sly, Edith Gabriela. Universidad Nacional de Tucumán. Facultad de Odontología; Argentina
dc.description.fil
Fil: Kaplan, Andrea Edith. Universidad de Buenos Aires; Argentina
dc.description.fil
Fil: Missana, Liliana Raquel. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Planta Piloto de Procesos Industriales Microbiológicos; Argentina. Universidad Nacional de Tucumán; Argentina
dc.journal.title
Acta Odontológica Latinoamericana
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://ref.scielo.org/23cjyf
Archivos asociados