Experimental monitoring and post-occupancy evaluation of a non-domestic solar building in the central region of Argentina
Fecha de publicación:
04/2015
Editorial:
Elsevier
Revista:
Energy and Buildings
ISSN:
0378-7788
Idioma:
Inglés
Tipo de recurso:
Artículo publicado
Clasificación temática:
Resumen
Previous experience in designing and monitoring bioclimatic buildings in central Argentina suggests that their thermal behavior is a matter of concern and that further research is needed. Thus, the objectives of this work are: to describe the design and the post-occupancy evaluation of a new non-domestic solar building in a continental semiarid region of central Argentina (37°38′ latitude S, 63°34′ longitude, 175 m above sea level), to analyze the building's hygrothermal and energy performance, and to estimate the PMV and PPD. The design guidelines were: to minimize the consumption of conventional energy in thermal-lighting conditioning, to use traditional technology, to maximize the thermal comfort, and to reach an extra-cost lower than 10%. The post-occupancy monitoring of the building was performed along one complete year (August 9th 2011-August 18th 2012). Data-loggers were installed in each functional area to sense the indoor temperature and relative humidity at time steps of 10 min. A meteorological station was installed near the building. The experimental results showed that during winter the average temperature in the areas of permanent use was 20.3 °C (average outdoor temperature: 10.1 °C) and the heating energy consumption was around 73.5 kW h/m2. During summer the average indoor temperature in the building was 26.9 °C, 1.7 °C below the outdoor temperature average (28.6°C); cooling systems were turned on when the indoor temperature reached 28 °C, at approximately 11:30 AM, when the outdoor air temperature exceeded 30 °C. Mechanical cooling consumed around 59% of the daily electricity consumption. The PDD results obtained for winter and summer representative days meet the requirements of ISO Norm 7730. Heating and cooling energy saving was around 63% and 76.5% respectively. The monitoring showed that the thermal behavior and energy performance met the expectations of both designers and users, and it is considered satisfactory and promising for low-energy consumption buildings.
Archivos asociados
Licencia
Identificadores
Colecciones
Articulos(SEDE CENTRAL)
Articulos de SEDE CENTRAL
Articulos de SEDE CENTRAL
Citación
Filippin, Maria Celina; Flores Larsen, Silvana Elinor; Marek, Marcelo Aurelio; Experimental monitoring and post-occupancy evaluation of a non-domestic solar building in the central region of Argentina; Elsevier; Energy and Buildings; 92; 4-2015; 267-281
Compartir
Altmétricas