Mostrar el registro sencillo del ítem

dc.contributor.author
Catalfamo Formento, Paola Andrea Lucia  
dc.contributor.author
Acevedo, Rubén Carlos  
dc.contributor.author
Ghoussayni, Salim  
dc.contributor.author
Ewins, David  
dc.date.available
2018-01-17T19:28:56Z  
dc.date.issued
2014-03  
dc.identifier.citation
Ewins, David; Acevedo, Rubén Carlos; Catalfamo Formento, Paola Andrea Lucia; Ghoussayni, Salim; Gait Event Detection on Stair Walking Using a Rate Gyroscope; Molecular Diversity Preservation International; Sensors; 14; 3; 3-2014; 5470-5485  
dc.identifier.issn
1424-8220  
dc.identifier.uri
http://hdl.handle.net/11336/33678  
dc.description.abstract
Gyroscopes have been proposed as sensors for ambulatory gait analysis and functional electrical stimulation systems. These applications often require detection of the initial contact (IC) of the foot with the floor and/or final contact or foot off (FO) from the floor during outdoor walking. Previous investigations have reported the use of a single gyroscope placed on the shank for detection of IC and FO on level ground and incline walking. This paper describes the evaluation of a gyroscope placed on the shank for determination of IC and FO in subjects ascending and descending a set of stairs. Performance was compared with a reference pressure measurement system. The absolute mean difference between the gyroscope and the reference was less than 45 ms for IC and better than 135 ms for FO for both activities. Detection success was over 93%. These results provide preliminary evidence supporting the use of a gyroscope for gait event detection when walking up and down stairs.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Molecular Diversity Preservation International  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by/2.5/ar/  
dc.subject
Gait Event Detection  
dc.subject
Initial Contact  
dc.subject
Foot Off  
dc.subject
Gyroscopes  
dc.subject
Algorithm  
dc.subject
Ambulatory System  
dc.subject
Gait Analysis  
dc.subject
Stairs Ascent  
dc.subject
Stairs Descent  
dc.subject
Electrical Stimulation  
dc.subject
Foot Drop  
dc.subject.classification
Ortopedia  
dc.subject.classification
Medicina Clínica  
dc.subject.classification
CIENCIAS MÉDICAS Y DE LA SALUD  
dc.title
Gait Event Detection on Stair Walking Using a Rate Gyroscope  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2018-01-11T13:46:31Z  
dc.journal.volume
14  
dc.journal.number
3  
dc.journal.pagination
5470-5485  
dc.journal.pais
Suiza  
dc.journal.ciudad
Basilea  
dc.description.fil
Fil: Catalfamo Formento, Paola Andrea Lucia. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; Argentina. University of Surrey; Reino Unido. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina  
dc.description.fil
Fil: Acevedo, Rubén Carlos. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; Argentina  
dc.description.fil
Fil: Ghoussayni, Salim. University of Surrey; Reino Unido  
dc.description.fil
Fil: Ewins, David. University of Surrey; Reino Unido  
dc.journal.title
Sensors  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://www.mdpi.com/1424-8220/14/3/5470  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.3390/s140305470