Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Artículo

Alluvial fan deposition along a rift depocentre border from the Neuquén Basin, Argentina

Muravchik, MartinIcon ; Bilmes, AndrésIcon ; D'Elia, LeandroIcon ; Franzese, Juan RafaelIcon
Fecha de publicación: 03/2014
Editorial: Elsevier Science
Revista: Sedimentary Geology
ISSN: 0037-0738
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Meteorología y Ciencias Atmosféricas

Resumen

The interaction between hangingwall block rotation and alluvial deposition is examined from Late Triassic–Early Jurassic successions exposed along the Catán Lil half-graben border fault system in the Neuquén Basin, Argentina. Analysis of transport and depositional processes, clast composition and rock body geometry allowed the identification of three distinctive fan-shaped alluvial units. The contrasting lithologic nature of the basement (igneous-metamorphic) and syn-rift fill (volcanic and volcanic-derived) permits detailed studies of clast provenance. The origin of each alluvial system (footwall- vs. hangingwall-derived) can thus be verified. A simple method was implemented to establish the geometry of each alluvial unit by comparing the stereographic projection of its bedding to that of an idealised fan shaped body. Results show that the three alluvial systems occupied the same relative location in the rift depocentre. Unit 1 is interpreted as an alluvial fan orientated transverse to the depocentre border fault system and fed from the footwall. Non-cohesive debris flow deposition was the dominant process in this environment. Unit 2 is interpreted as a mainly hangingwall-fed alluvial fan, parallel to the depocentre border fault system and shows an upward decrease in footwall-derived clasts. Hyperconcentrated flow was the principal transport process. Unit 3 represents a fan delta, parallel to the depocentre border fault system. Its components are completely hangingwall-derived and hyperconcentrated flow deposition was the dominant process. Differences in grain-size, composition, transport directions and fan body geometry are proved to be directly linked to variations in ground tilting induced by the direction of hangingwall block rotation in an endorheic rift depocentre.
Palabras clave: Alluvial Processes , Structural Controls , Alluvial Fan Orientation , Syn-Rift , Neuquén Basin
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 6.203Mb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/32411
DOI: http://dx.doi.org/10.1016/j.sedgeo.2013.12.007
URL: http://www.sciencedirect.com/science/article/pii/S0037073813002315
Colecciones
Articulos(CIG)
Articulos de CENTRO DE INVEST.GEOLOGICAS (I)
Citación
Franzese, Juan Rafael; D'Elia, Leandro; Bilmes, Andrés; Muravchik, Martin; Alluvial fan deposition along a rift depocentre border from the Neuquén Basin, Argentina; Elsevier Science; Sedimentary Geology; 301; 3-2014; 70-89
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES