Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Artículo

Estimación de interferencias en la determinación de fructosamina en suero de felinos y caninos

Título: Estimation of interferences in the determination of fructosamine of feline and canine serum
Colla, Cora; Rodriguez, Joaquin ValentinIcon ; Rabe, Gabriela; Patalano, Claudio; Perassi, María Eugenia; Bordone, Facundo; Cerruti, Jorgelina
Fecha de publicación: 10/2014
Editorial: Universidad de Buenos Aires. Facultad de Ciencias Veterinarias
Revista: InVet
ISSN: 1514-6634
e-ISSN: 1668-3498
Idioma: Español
Tipo de recurso: Artículo publicado
Clasificación temática:
Otras Ciencias Veterinarias

Resumen

 
La concentración de fructosamina en suero es útil para monitorear el control de la glucemia en un período precedente.En muestras de sangre, la presencia de hemoglobina y bilirrubina pueden causar interferencias en técnicas analíticas diagnósticas. Por ello, el objetivo de este trabajo fue evaluar la posible interferencia al medir fructosamina sérica de gatos y perros clínicamente sanos. Se construyeron interferogramas, agregando concentraciones crecientes del posible interferente a pools de sueros de ambas especies. Se estudiaron concentraciones de hemoglobina desde 0.19 a 7.5 g/l en felinos, y de 0.16 a 6.10 g/l en caninos. Para bilirrubina, desde 6 a 600 mg/l, en ambas especies. Los resultados mostraron interferencia positiva y aditiva de hemoglobina en felinos (≥1.60 g/l) e interferencia negativa en caninos (≥1.20 g/l). En ambas especies se observaron interferencias positivas y aditivas para bilirrubina en el rango de concentraciones estudiadas (≥30 mg/l para felinos y ≥150 mg/l para caninos).
 
The fructosamine serum concentration reflects the degree of glycemic control obtained during a preceding period. Usually, the presence of hemoglobin or bilirrubin in blood samples, could cause interferences in the laboratory analytical assays.Thus, we investigated the possible interferences on fructosamine determinations in serum from healthy cats and dogs. To testing and quantify the interference, we construct interferograms adding increased concentrations of hemoglobin or bilirrubin to serum pools of cats or dogs. We tested serum hemoglobin concentrations from 0.19 to 7.5 g/l in feline sera and 0.16 to 6.10 g/l in canine sera. The bilirrubin testing was done from 6 to 600 mg/l in both species sera. The results had shown a hemoglobin positive and additive interference in feline sera (≥1.60 g/l) and a negative interference in canine sera (≥1.20 g/l). In addition both species had shown positive and additive bilirrubin interferences (≥30 mg/l for feline sera and ≥150 mg/l for canine sera).
 
Palabras clave: Interferencias , Fructosamina , Caninos , Felinos
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 287.6Kb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/31007
URL: http://ref.scielo.org/89q2ch
Colecciones
Articulos(CCT - ROSARIO)
Articulos de CTRO.CIENTIFICO TECNOL.CONICET - ROSARIO
Citación
Cerruti, Jorgelina; Bordone, Facundo; Perassi, María Eugenia; Patalano, Claudio; Rabe, Gabriela; Rodriguez, Joaquin Valentin; et al.; Estimación de interferencias en la determinación de fructosamina en suero de felinos y caninos; Universidad de Buenos Aires. Facultad de Ciencias Veterinarias; InVet; 16; 10-2014; 63-68
Compartir

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES