Non-Linear 3D Impedance Spectroscopy

Zamora, Martín LucasIcon ; Trujillo, Ricardo MatiasIcon ; Felice, Carmelo JoseIcon
Fecha de publicación: 08/2014
Editorial: Institute of Electrical and Electronics Engineers
Revista: IEEE Latin America Transactions
ISSN: 1548-0992
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Biofísica

Resumen

Non-linear Dielectric spectroscopy of Biological suspensions was first proposed by the Woodward and Kell group. The above mentioned arose as a technique able to monitor the enzymes state placed in the cell membrane of the biological tissue. This technique is limited to such enzymes because an external low frequency electrical field notably disturbs the membrane's electrical entourage. This kind of interactions can be monitor if the system generates current harmonics. This phenomenon was theorized by Astumian and Robertson. Treo, on his work suggests that the harmonics are originated at the interface and altered by the microorganism presence. Then Ruiz developed a fast method to detect the global non-linearity of a biological suspension. Nevertheless, on these works, the non-linearity interference due to the electrode-electrolyte interface was not controlled. The observed response is the result of the interface modulation because of the microorganism presence. On our work, we employed a tripolar measurement cell. The working electrode (WE) is a gold disc, the counter electrode (CE) is made of stainless steel and the reference electrode (RE) is a standard Ag/AgCl electrode. 1.74 g of lyophilized Saccharomyces cerevisiae was dissolved in 90 ml of saline medium. A frequency (0.1 - 1000 Hz) and tension AC (0- 600 mV) sweep was carried out without DC polarization. The first 5 output current harmonics were monitored. Results would indicate that it was successfully possible to measure the non-linearity due to only the yeasts cells, without the non-linear interference of the electrode - electrolyte interface.
Palabras clave: Yeast , Bioimpedance , Non Linear , Biological
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 512.4Kb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/30528
DOI: http://dx.doi.org/10.1109/TLA.2014.6872902
URL: http://ieeexplore.ieee.org/document/6872902/
Colecciones
Articulos(INSIBIO)
Articulos de INST.SUP.DE INVEST.BIOLOGICAS
Citación
Zamora, Martín Lucas; Trujillo, Ricardo Matias; Felice, Carmelo Jose; Non-Linear 3D Impedance Spectroscopy; Institute of Electrical and Electronics Engineers; IEEE Latin America Transactions; 12; 5; 8-2014; 895-898
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES