Artículo
Techniques for Measuring Aerosols using the Central Laser Facility at the Pierre Auger Observatory
Abreu, P.; Aglietta, M.; Ahlers, M.; Ahn, E. J.; Albuquerque, I. F. M.; Allekotte, Ingomar; Almela, Daniel Alejandro
; Asorey, Hernán Gonzalo
; Bertou, Xavier Pierre Louis
; Dasso, Sergio Ricardo
; de la Vega, Gonzalo Andrés
; Dova, Maria Teresa
; Etchegoyen, Alberto
; Figueira, Juan Manuel
; Filevich, Alberto
; Garcia, Beatriz Elena
; Golup, Geraldina Tamara
; Gómez Albarracín, Flavia Alejandra
; Gomez Berisso, Mariano
; Guardincerri, Yann
; Hansen, Patricia Maria
; Harari, Diego Dario
; Jarne, Cecilia Gisele
; Josebachuili Ogando, Mariela Gisele
; Lucero, Luis Agustin
; Mariazzi, Analisa Gabriela
; Masías Meza, Jimmy Joel
; Melo, Diego Gabriel
; Micheletti, Maria Isabel
; Mollerach, Maria Silvia
; Moreno, Juan Cruz
; Pallotta, Juan Vicente
; Piegaia, Ricardo Nestor
; Pieroni, Pablo Emanuel
; Platino, Manuel
; Quel, Eduardo Jaime
; Ravignani Guerrero, Diego; Roulet, Esteban
; Rovero, Adrian Carlos
; Sanchez, Federico Andrés
; Sciutto, Sergio Juan
; Sidelnik, Iván Pedro
; Suarez, Federico
; Supanitsky, Alberto Daniel
; Tapia Casanova, Alex Marcelo
; Tiffenberg, Javier Sebastian
; Tueros, Matias Jorge
; Wahlberg, Hernan Pablo
; Wundheiler, Brian
; Yelós, Laura Diana
; Zepeda, A.; Zhou, J.; Zhu, Y.; Zimbres Silva, M.; Ziolkowski, M.
Fecha de publicación:
04/2013
Editorial:
IOP Publishing
Revista:
Journal of Instrumentation
ISSN:
1748-0221
Idioma:
Inglés
Tipo de recurso:
Artículo publicado
Clasificación temática:
Resumen
The Pierre Auger Observatory in Malargüe, Argentina, is designed to study the properties of ultra-high energy cosmic rays with energies above 10E18eV. It is a hybrid facility that employs a Fluorescence Detector to perform nearly calorimetric measurements of Extensive Air Shower energies. To obtain reliable calorimetric information from the FD, the atmospheric conditions at the observatory need to be continuously monitored during data acquisition. In particular, light attenuation due to aerosols is an important atmospheric correction. The aerosol concentration is highly variable, so that the aerosol attenuation needs to be evaluated hourly. We use light from the Central Laser Facility, located near the center of the observatory site, having an optical signature comparable to that of the highest energy showers detected by the FD. This paper presents two procedures developed to retrieve the aerosol attenuation of fluorescence light from CLF laser shots. Cross checks between the two methods demonstrate that results from both analyses are compatible, and that the uncertainties are well understood. The measurements of the aerosol attenuation provided by the two procedures are currently used at the Pierre Auger Observatory to reconstruct air shower data.
Archivos asociados
Licencia
Identificadores
Colecciones
Articulos(CCT - PATAGONIA NORTE)
Articulos de CTRO.CIENTIFICO TECNOL.CONICET - PATAGONIA NORTE
Articulos de CTRO.CIENTIFICO TECNOL.CONICET - PATAGONIA NORTE
Articulos(IAFE)
Articulos de INST.DE ASTRONOMIA Y FISICA DEL ESPACIO(I)
Articulos de INST.DE ASTRONOMIA Y FISICA DEL ESPACIO(I)
Articulos(IFIR)
Articulos de INST.DE FISICA DE ROSARIO (I)
Articulos de INST.DE FISICA DE ROSARIO (I)
Articulos(IFLP)
Articulos de INST.DE FISICA LA PLATA
Articulos de INST.DE FISICA LA PLATA
Articulos(ITEDA)
Articulos de INSTITUTO DE TEC. EN DETECCION Y ASTROPARTICULAS
Articulos de INSTITUTO DE TEC. EN DETECCION Y ASTROPARTICULAS
Articulos(UNIDEF)
Articulos de UNIDAD DE INVESTIGACION Y DESARROLLO ESTRATEGICOS PARA LA DEFENSA
Articulos de UNIDAD DE INVESTIGACION Y DESARROLLO ESTRATEGICOS PARA LA DEFENSA
Citación
Abreu, P.; Aglietta, M.; Ahlers, M.; Ahn, E. J.; Albuquerque, I. F. M.; et al.; Techniques for Measuring Aerosols using the Central Laser Facility at the Pierre Auger Observatory; IOP Publishing; Journal of Instrumentation; 8; 4-2013; 4009-4009
Compartir
Altmétricas