Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Artículo

Simplified Extense Source Model for Photoreactor Analysis and Design”.

Irazoqui, Horacio AntonioIcon ; Isla, Miguel AngelIcon ; Cassano, Alberto EnriqueIcon
Fecha de publicación: 11/2000
Editorial: American Chemical Society
Revista: Industrial & Engineering Chemical Research
ISSN: 0888-5885
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Otras Ingeniería Química

Resumen

Most of the research work on photoreactor analysis, modeling, and design published so far relies on two approaches to represent the emission of tubular radiation sources:  the line (linear) source models (LSMs) and the extense (three-dimensional) source models (ESMs). It is widely recognized that the ESMs give the more realistic representation of the emission phenomenon so far; however, they are rather difficult to use in some applications, especially when indirect radiation plays a dominant role. On the other hand, LSMs are simpler, and in some cases, mostly when reflected radiation has not been involved, they have been used with success. In this work, the simplified extense model (SEM), systematically derived from the extense source model with voluminal emission (ESVE), is proposed. The SEM retains all of the simplicity of the LSM for the prediction of the direct radiation contribution, while rendering closed mathematical expressions that give a more realistic and often very accurate representation of the reflected radiation inside reflecting cylindrical cavities with elliptical cross sections. The average incident radiation on the reactor surface at the midreactor length as predicted with the SEM never differs by more than 12% of the average value computed with the ESVE. Moreover, for different sets of frequently used parameter values characterizing the shape of the elliptical mirror and the reactor, the compared average values agreed within 5% of the reference value given by the ESVE. Within the same parameter range and for eccentricities of about e = 0.4, nonaveraged values of the incident radiation computed at different points on the external surface of the reactor wall at the midreactor height position using the SEM and the ESVE models agreed remarkably well, to the point that, under certain circumstances, the profiles obtained are not easily distinguishable from one another. The SEM brings together simplicity of implementation with desirable accuracy for a wide set of values of the apparatus parameters used to illustrate the proposal.
Palabras clave: Analysis , Model , Photoreactor , Radiation
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 139Kb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/27806
DOI: http://dx.doi.org/10.1021/ie9907876
Colecciones
Articulos(INTEC)
Articulos de INST.DE DES.TECNOL.PARA LA IND.QUIMICA (I)
Citación
Irazoqui, Horacio Antonio; Isla, Miguel Angel; Cassano, Alberto Enrique; Simplified Extense Source Model for Photoreactor Analysis and Design”.; American Chemical Society; Industrial & Engineering Chemical Research; 39; 11; 11-2000; 4260-4271
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES