Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Evento

Intraocular light scatter in eyes with Boston type 1 Keratoprosthesis

Shorter, Ellen; Karas, Faras; Arteaga, Andrea; Barrionuevo, Pablo AlejandroIcon ; Cao, Dingcai; McAnany, J. Jason; Cortina, Maria S.
Tipo del evento: Encuentro
Nombre del evento: Academy 2018
Fecha del evento: 07/11/2018
Institución Organizadora: American Academy of Optometry;
Título del Libro: American Academy of Optometry 2018: Scientific program
Editorial: American Academy of Optometry
Idioma: Inglés
Clasificación temática:
Oftalmología

Resumen

Purpose Boston Keratoprosthesis (KPro) has been proven to be a viable option for visual rehabilitation in patients with poor prognosis for penetrating keratoplasty, and its use has steadily increased during the past decade. An improved design and postoperative management have led to longer retention rates, fewer complications and overall better outcomes. Many patients complain of significant glare and visual dysfunction despite improved visual acuity. This issue motivated us to objectively measure light scatter in eyes with KPro devices.Methods Light scatter was measured using OCULUS C-Quant device (Arlington, WA). The amount of scatter was compared between 21 eyes with Boston KPro Type 1 and VA of 20/150 or better to 13 healthy control eyes. The measurements were repeated at more than one visit. Scatter measurements were also repeated on 11 eyes with Boston KPro Type 1 using a black iris occluder Orion Prosthetic contact lens(Orion Vision Group, Marietta, GA). The contact lens was polymacon 38% material, plano power, base curve 8.6, diameter 14.3, 12.25 black occluder iris with a 5.0mm clear pupil.Results The mean age of the KPro group was 55.5 years and 53.6 years for the control group. Mean VA was 0.47 logMAR and 0.00 logMAR for the KPro and control group respectively. Intraocular light scatter was found to be significantly higher in patients with KPro compared to healthy control subjects (logS values of 2.34 ± 0.15 and 1.29 ± 0.17 respectively, p<0.01). Light scatter in eyes with PMMA KPro devices (logS 2.49 ± 0.19; n=16) was higher than in eyes with titanium KPro devices (logS 1.87 ± 0.15; n=5). The LogS value was significantly lower for eyes with PMMA backplate KPro devices fit with iris occluder prosthetic lens (1.71 vs 2.42, P = < 0.05; n=11).Conclusion Glare is a common complaint by many patients with KPro devices. Light scatter measured in this study showed significantly higher values in eyes with KPro devices compared to healthy eyes. Possibly due to its opaque nature, the titanium backplate model appears to produce less light scatter than PMMA backplate model. Prosthetic contact lenses may serve a role to reduce light scatter in individuals with KPro devices and should be considered as an option for symptomatic patients.
Palabras clave: SCATTERING , KERATOPROSTHESIS , VISION , GLARE
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 181.6Kb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/276987
URL: https://aaopt.org/past-meeting-abstract-archives/?SortBy=Year=2018&Authors=Barri
Colecciones
Eventos(ILAV)
Eventos de INST.DE INVESTIGACION EN LUZ, AMBIENTE Y VISION
Citación
Intraocular light scatter in eyes with Boston type 1 Keratoprosthesis; Academy 2018; San Antonio; Estados Unidos; 2018; 1-3
Compartir

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES