An ultrasonic-accelerated oxidation method for determining the oxidative stability of biodiesel

Avila Orozco, Francisco DavidIcon ; Sousa, Antonio C.; Domini, Claudia ElizabethIcon ; Araújo, Mário César U.; Fernández Band, Beatriz SusanaIcon
Fecha de publicación: 11/2012
Editorial: Elsevier
Revista: Ultrasonics Sonochemistry
ISSN: 1350-4177
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Otras Ciencias Químicas

Resumen

Biodiesel is considered an alternative energy because it is produced from fats and vegetable oils by means of transesterification. Furthermore, it consists of fatty acid alkyl esters (FAAS) which have a great influence on biodiesel fuel properties and in the storage lifetime of biodiesel itself. The biodiesel storage stability is directly related to the oxidative stability parameter (Induction Time – IT) which is determined by means of the Rancimat® method. This method uses condutimetric monitoring and induces the degradation of FAAS by heating the sample at a constant temperature. The European Committee for Standardization established a standard (EN 14214) to determine the oxidative stability of biodiesel, which requires it to reach a minimum induction period of 6 h as tested by Rancimat® method at 110 °C. In this research, we aimed at developing a fast and simple alternative method to determine the induction time (IT) based on the FAAS ultrasonic-accelerated oxidation. The sonodegradation of biodiesel samples was induced by means of an ultrasonic homogenizer fitted with an immersible horn at 480 Watts of power and 20 duty cycles. The UV–Vis spectrometry was used to monitor the FAAS sonodegradation by measuring the absorbance at 270 nm every 2. Biodiesel samples from different feedstock were studied in this work. In all cases, IT was established as the inflection point of the absorbance versus time curve. The induction time values of all biodiesel samples determined using the proposed method was in accordance with those measured through the Rancimat® reference method by showing a R2 = 0.998.
Palabras clave: Biodiesel , Sondegradation , Experimental Design , Oxidative Stability , Fatty Acid Alkyl Esters , Uv-Vis Spectrophotometry
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 621.2Kb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Atribución-NoComercial-SinDerivadas 2.5 Argentina (CC BY-NC-ND 2.5 AR)
Identificadores
URI: http://hdl.handle.net/11336/26232
DOI: http://dx.doi.org/10.1016/j.ultsonch.2012.10.012
URL: http://www.sciencedirect.com/science/article/pii/S1350417712002374
Colecciones
Articulos(INQUISUR)
Articulos de INST.DE QUIMICA DEL SUR
Citación
Avila Orozco, Francisco David; Sousa, Antonio C.; Domini, Claudia Elizabeth; Araújo, Mário César U.; Fernández Band, Beatriz Susana; An ultrasonic-accelerated oxidation method for determining the oxidative stability of biodiesel; Elsevier; Ultrasonics Sonochemistry; 20; 3; 11-2012; 820-825
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES