Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Artículo

Mg ZX10 alloy for biomedical applications: Surface characterization and comparative corrosion studies under simulated biological conditions

Malvestiti, LucianaIcon ; Tano de la Hoz, María FlorenciaIcon ; Usach, VaninaIcon ; Pastore, Juan IgnacioIcon ; Setton, Clara PatriciaIcon ; Katunar, Maria RosaIcon ; Ceré, SilviaIcon
Fecha de publicación: 03/2024
Editorial: Elsevier Science SA
Revista: Materials Chemistry and Physics
ISSN: 0254-0584
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Otras Ingeniería Eléctrica, Ingeniería Electrónica e Ingeniería de la Información

Resumen

Biodegradable magnesium (Mg)-based alloys emerge as potential intracorporeal implants for clinical application in bone tissue, the cardiovascular and the nervous systems. The surfaces of control (non-sterilized) and sterilized (180 °C 1 h) Mg ZX10 alloy were studied. The alloy evolution in SBF (simulated saline solution) and in DMEM (Dulbecco´s Modified Eagle Medium) with fetal calf serum (FCS) was investigated using: Raman spectroscopy, FTIR-ATR, electrochemical assays and scanning electron microscopy (SEM). The Mg ZX10 microstructure analysis revealed an average grain size of 23.4 ± 11.02 and 31.6 ± 13.07 μm, considering the minor and major axis, respectively. In addition, the Mg ZX10 microstructure exhibited a homogeneous grain distribution. The contact angle formed between the water and the surface of control Mg ZX10 and sterilized were 32.24° ± 1.53 and 46.76° ± 0.83, respectively. Consequently, both groups of samples exhibited hydrophilic surfaces. Furthermore, the free surface energy of control Mg ZX10 was 63.23 ± 0.72 mN/m and sterilized Mg ZX10 was 52.31 mN/m ± 1.25, those energy values were in agreement with previous reports. Upon immersion in SBF, Raman spectroscopy detected the presence of magnesium oxides-hydroxides, phosphates and carbonates compounds in both groups of samples without significant differences. FTIR spectra of the sterilized alloys, after immersion in DMEM + FCS, showed the presence of amide and carbon-carbon bonds, magnesium-oxides, as well as phosphates and carbonates groups. These findings suggested the deposition of organic and inorganic compounds on the alloy surface. Electrochemical assays carried out in SBF demonstrated a slight reduction in the degradation of the sterilized alloy compared to control Mg ZX10. Moreover, a substantial decrease in the corrosion behavior of the sterilized alloy immersed in DMEM + FCS with respect to the same alloy immersed in SBF was observed. SEM images showed that the alloy, previously immersed in SBF, exhibited degradation cracks. Contrary, the sterilized alloy surface immersed in DMEM + FCS was more homogenous with deposits of structures similar to hybrid nanoflowers. Based on these results, this sterilization process does not alter the chemistry of Mg ZX10 alloy surface and, even, its application exhibits an advantage since the high corrosion rate of Mg in physiological media. Furthermore, the organic-inorganic structures adsorbed, after alloy immersion in DMEM + FCS, could decrease corrosion behavior.
Palabras clave: CORROSION BEHAVIOR , IN VITRO ASSAYS , INTERFACE EVENTS , MG-BASED ALLOY , STERILIZATION PROCESS
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 1.958Mb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/260930
URL: https://linkinghub.elsevier.com/retrieve/pii/S0254058424000579
DOI: http://dx.doi.org/10.1016/j.matchemphys.2024.128933
Colecciones
Articulos(ICYTE)
Articulos de INSTITUTO DE INVESTIGACIONES CIENTIFICAS Y TECNOLOGICAS EN ELECTRONICA
Articulos(INTEMA)
Articulos de INST.DE INV.EN CIENCIA Y TECNOL.MATERIALES (I)
Articulos(IQUIFIB)
Articulos de INST.DE QUIMICA Y FISICO-QUIMICA BIOLOGICAS "PROF. ALEJANDRO C. PALADINI"
Citación
Malvestiti, Luciana; Tano de la Hoz, María Florencia; Usach, Vanina; Pastore, Juan Ignacio; Setton, Clara Patricia; et al.; Mg ZX10 alloy for biomedical applications: Surface characterization and comparative corrosion studies under simulated biological conditions; Elsevier Science SA; Materials Chemistry and Physics; 315; 3-2024; 1-41
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES