Mostrar el registro sencillo del ítem

dc.contributor.author
Longhi, Silvia Andrea  
dc.contributor.author
García Casares, Lady Juliette  
dc.contributor.author
Muñoz Calderon, Arturo Alejandro  
dc.contributor.author
Irazu, Lucía  
dc.contributor.author
Rodríguez, Marcelo A.  
dc.contributor.author
Landfried, Gustavo Andrés  
dc.contributor.author
Alonso Padilla, Julio  
dc.contributor.author
Schijman, Alejandro Gabriel  
dc.date.available
2025-05-09T11:41:11Z  
dc.date.issued
2024-12  
dc.identifier.citation
Longhi, Silvia Andrea; García Casares, Lady Juliette; Muñoz Calderon, Arturo Alejandro; Irazu, Lucía; Rodríguez, Marcelo A.; et al.; Interlaboratory Harmonization Study and Prospective Evaluation of the PURE–Trypanosoma cruzi–Loop-Mediated Isothermal Amplification Assay for Detecting Parasite DNA in Newborn's Dried Blood Spots; American Society of Investigative Pathology; Journal Of Molecular Diagnostics; 26; 12; 12-2024; 1055-1064  
dc.identifier.issn
1525-1578  
dc.identifier.uri
http://hdl.handle.net/11336/260881  
dc.description.abstract
Timely diagnosis of vertical Trypanosoma cruzi infections involves microscopy-based detection of circulating parasites from peripheral blood, which lacks sensitivity and is operator dependent. Consequently, most children born to T. cruzi-infected mothers are required to undergo serological testing after 9 months, which risks loss to follow-up. Alternatively, the loop-mediated isothermal amplification (LAMP) test for T. cruzi DNA offers high analytical and clinical performance and is easy to use in low-complexity laboratories. Recently, we optimized this technique using an ultrarapid DNA extraction method combined with the LAMP in dried blood spots (DBSs) on Flinders Technology Associates cards. The procedure has been implemented in 10 public maternities across Paraguay, Bolivia, and Argentina, involving the training of 14 technicians. Operators' performance was evaluated using a standardized DBS testing panel for harmonization, including negative controls and DBS samples artificially contaminated with T. cruzi at 50 and 20 cells/mL. There was strong agreement (ĸ = 0.924) for controls and 50 cells/mL samples, and good agreement (ĸ = 0.718) across all testing panels, even at the detection limit of the test. A prospective study collected 306 DBSs from 222 newborns at birth and/or 2 months, detecting T. cruzi microscopically in four cases. LAMP identified eight positive cases and perfectly aligned with real-time PCR (ĸ = 1), demonstrating higher sensitivity than microscopic observation for early detection of infection in infants.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
American Society of Investigative Pathology  
dc.rights
info:eu-repo/semantics/restrictedAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
Trypanosoma cruzi infection  
dc.subject
LAMP  
dc.subject
Molecular diagnosis  
dc.subject
Congenitasl chagas disease  
dc.subject.classification
Enfermedades Infecciosas  
dc.subject.classification
Ciencias de la Salud  
dc.subject.classification
CIENCIAS MÉDICAS Y DE LA SALUD  
dc.title
Interlaboratory Harmonization Study and Prospective Evaluation of the PURE–Trypanosoma cruzi–Loop-Mediated Isothermal Amplification Assay for Detecting Parasite DNA in Newborn's Dried Blood Spots  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2025-05-07T12:46:16Z  
dc.journal.volume
26  
dc.journal.number
12  
dc.journal.pagination
1055-1064  
dc.journal.pais
Estados Unidos  
dc.description.fil
Fil: Longhi, Silvia Andrea. Consejo Nacional de Investigaciones Científicas y Técnicas. Instituto de Investigaciones en Ingeniería Genética y Biología Molecular "Dr. Héctor N. Torres"; Argentina  
dc.description.fil
Fil: García Casares, Lady Juliette. Consejo Nacional de Investigaciones Científicas y Técnicas. Instituto de Investigaciones en Ingeniería Genética y Biología Molecular "Dr. Héctor N. Torres"; Argentina  
dc.description.fil
Fil: Muñoz Calderon, Arturo Alejandro. Consejo Nacional de Investigaciones Científicas y Técnicas. Instituto de Investigaciones en Ingeniería Genética y Biología Molecular "Dr. Héctor N. Torres"; Argentina  
dc.description.fil
Fil: Irazu, Lucía. Dirección Nacional de Instituto de Investigación. Administración Nacional de Laboratorio e Instituto de Salud "Dr. C. G. Malbrán"; Argentina  
dc.description.fil
Fil: Rodríguez, Marcelo A.. Dirección Nacional de Instituto de Investigación. Administración Nacional de Laboratorio e Instituto de Salud "Dr. C. G. Malbrán"; Argentina  
dc.description.fil
Fil: Landfried, Gustavo Andrés. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina  
dc.description.fil
Fil: Alonso Padilla, Julio. Instituto de Salud Carlos III; España  
dc.description.fil
Fil: Schijman, Alejandro Gabriel. Consejo Nacional de Investigaciones Científicas y Técnicas. Instituto de Investigaciones en Ingeniería Genética y Biología Molecular "Dr. Héctor N. Torres"; Argentina  
dc.journal.title
Journal Of Molecular Diagnostics  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://linkinghub.elsevier.com/retrieve/pii/S1525157824002101  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.jmoldx.2024.08.007