dc.identifier.citation
Mercado, Maria Victoria; Flores Larsen, Silvana Elinor; Esteves Miramont, Alfredo; Filippin, Maria Celina; Dimensionamiento del panel radiante del Sistema de calefacción radiante solar pasivo; Asociación Argentina de Energía Solar; Avances en Energías Renovables y Medio Ambiente; 14; 11-2010; 31-38
dc.identifier.issn
0329-5184
dc.identifier.uri
http://hdl.handle.net/11336/259502
dc.description.abstract
Se ha estudiado el sistema de calefacción radiante solar pasivo para acondicionar locales sin disposición de una fachada hacia el ecuador. El presente trabajo analiza el dimensionamiento del panel radiante del sistema a partir del concepto de la asimetría radiante, ligado al confort térmico y con el intercambio radiante. Se analiza la relación de la asimetría radiante y el porcentaje de disconfort que propone las normas ISO 7730:1994 y ASHRAE 55, estableciendo como máximo una diferencia de temperatura entre cabeza y techo de 10ºC con un 20% de personas en disconfort. A partir de este dato se desarrolla el método de dimensionamiento analizando tres casos de estudio. De estos se advierte que la relación superficie panel-superficie cubierta del local debe mantenerse entre 1/8-1/4. Posteriormente, y utilizando una ecuación predictiva de la temperatura del panel elaborada a partir de un análisis multivariado, se dimensiona el sistema para un espacio diurno de una vivienda social del plan FONAVI, del cuál resulta que para maximizar el desempeño del sistema se pueden colocar dos dispositivos cubriendo 1/4 de la superficie del mismo. El local alcanza una temperatura operativa de 20.5, entrando de ésta manera en el rango de confort térmico para invierno.
dc.description.abstract
Previously the system radiant heating passive solar was studied for rooms without a facade to Ecuador. This paper analyzes the radiant panel sizing system based on the asymmetric heating’s concept. Examines the relationship of the radiant asymmetry and the percentage of discomfort proposed ISO 7730:1994 and ASHRAE 55 standards, setting a maximum temperature difference between head and top of 10 º C with 20% of people in discomfort. Since this information is developed the method of sizing by analyzing three case studies. rom these we see that the panel surface-local-surface cover must be maintained between 1/8-1/4. Then used an equation for predicting panel temperature drawn from a multivariate analysis. The system is dimensioned for a day room for social housing FONAVI plan, of which is that to maximize the performance of the system can place two devices covering one fourth of the surface. The local reaches an operating temperature of 20.5, entering this way in the range of thermal comfort in winter.
dc.format
application/pdf
dc.language.iso
spa
dc.publisher
Asociación Argentina de Energía Solar
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
SISTEMAS PASIVOS
dc.subject
CALEFACCIÓN RADIANTE
dc.subject
ASIMETRÍA RADIANTE
dc.subject
CONFORT TÉRMICO
dc.subject.classification
Ingeniería Arquitectónica
dc.subject.classification
Ingeniería Civil
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS
dc.title
Dimensionamiento del panel radiante del Sistema de calefacción radiante solar pasivo
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2025-01-17T13:59:10Z
dc.journal.volume
14
dc.journal.pagination
31-38
dc.journal.pais
Argentina
dc.journal.ciudad
Salta
dc.description.fil
Fil: Mercado, Maria Victoria. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mendoza. Instituto de Ciencias Humanas, Sociales y Ambientales; Argentina
dc.description.fil
Fil: Flores Larsen, Silvana Elinor. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Salta. Instituto de Investigaciones en Energía no Convencional. Universidad Nacional de Salta. Facultad de Ciencias Exactas. Departamento de Física. Instituto de Investigaciones en Energía no Convencional; Argentina
dc.description.fil
Fil: Esteves Miramont, Alfredo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mendoza. Instituto de Ciencias Humanas, Sociales y Ambientales; Argentina
dc.description.fil
Fil: Filippin, Maria Celina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
dc.journal.title
Avances en Energías Renovables y Medio Ambiente
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://www.asades.org.ar
Archivos asociados