Irastorza, Ramiro Miguel; Hadid, Claudio; Berjano, Enrique; Effect of dispersive electrode position (anterior vs. posterior) in epicardial radiofrequency ablation of ventricular wall: A computer simulation study; Wiley; International Journal for Numerical Methods in Biomedical Engineering; 40; 8; 7-2024; 1-13
dc.identifier.issn
2040-7939
dc.identifier.uri
http://hdl.handle.net/11336/257301
dc.description.abstract
An epicardial approach is often used in radiofrequency (RF) catheter ablation to ablate ventricular tachycardia when an endocardial approach fails. Our objective was to analyze the effect of the position of the dispersive patch (DP) on lesion size using computer modeling during epicardial approach. We compared the posterior position (patient's back), commonly used in clinical practice, to the anterior position (patient's chest). The model considered ventricular wall thicknesses between 4 and 8 mm, and electrode insertion depths between .3 and .7 mm. RF pulses were simulated with 20 W of power for 30 s duration. Statistically significant differences (P < .001) were found between both DP positions in terms of baseline impedance, RF current (at 15 s) and thermal lesion size. The anterior position involved lower impedance (130.8 ± 4.7 vs. 146.2 ± 4.9 Ω) and a higher current (401.5 ± 5.6 vs. 377.5 ± 5.1 mA). The anterior position created lesion sizes larger than the posterior position: 8.9 ± 0.4 vs. 8.4 ± 0.4 mm in maximum width, 8.6 ± 0.4 vs. 8.1 ± 0.4 mm in surface width, and 4.5 ± 0.4 vs. 4.3 ± 0.4 mm in depth. Our results suggest that: (1) the redirection of the RF currents due to repositioning the PD has little impact on lesion size and only affects baseline impedance, and (2) the differences in lesion size are only 0.5 mm wider and 0.2 mm deeper for the anterior position, which does not seem to have a clinical impact in the context of VT ablation.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Wiley

dc.rights
info:eu-repo/semantics/restrictedAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
COMPUTER MODELLING
dc.subject
DISPERSIVE ELECTRODE
dc.subject
EPICARDIAL ABLATION
dc.subject
VENTRICULAR TACHYCARDIA
dc.subject.classification
Otras Ingeniería Eléctrica, Ingeniería Electrónica e Ingeniería de la Información

dc.subject.classification
Ingeniería Eléctrica, Ingeniería Electrónica e Ingeniería de la Información

dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS

dc.title
Effect of dispersive electrode position (anterior vs. posterior) in epicardial radiofrequency ablation of ventricular wall: A computer simulation study
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2025-03-26T19:44:02Z
dc.identifier.eissn
2040-7947
dc.journal.volume
40
dc.journal.number
8
dc.journal.pagination
1-13
dc.journal.pais
Estados Unidos

dc.description.fil
Fil: Irastorza, Ramiro Miguel. Universidad Tecnológica Nacional. Facultad Regional La Plata. Departamento de Ingeniería Mecánica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Física de Líquidos y Sistemas Biológicos. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Instituto de Física de Líquidos y Sistemas Biológicos; Argentina
dc.description.fil
Fil: Hadid, Claudio. Gobierno de la Ciudad Autonoma de Buenos Aires. Hospital General de Agudos Doctor Cosme Argerich.; Argentina
dc.description.fil
Fil: Berjano, Enrique. Universidad Politécnica de Valencia; España
dc.journal.title
International Journal for Numerical Methods in Biomedical Engineering
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://onlinelibrary.wiley.com/doi/10.1002/cnm.3847
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1002/cnm.3847
Archivos asociados