Mostrar el registro sencillo del ítem

dc.contributor.author
Carrizo, Álvaro D.  
dc.contributor.author
Lobo Marquez, Lilia L.  
dc.contributor.author
Socolsky, Gustavo  
dc.contributor.author
Hautecur, Tadeo G.  
dc.contributor.author
Orellana, Sergio E.  
dc.contributor.author
Joo Turoni, Claudio Martín  
dc.date.available
2025-03-18T10:53:49Z  
dc.date.issued
2023-03  
dc.identifier.citation
Carrizo, Álvaro D.; Lobo Marquez, Lilia L.; Socolsky, Gustavo; Hautecur, Tadeo G.; Orellana, Sergio E. ; et al.; Evaluación de la función ventricular en la Hipertensión Pulmonar por Resonancia Magnética Cardíaca; Sociedad Argentina de Radiología; Revista Argentina de Radiología; 87; 1; 3-2023; 3-10  
dc.identifier.issn
0048-7619  
dc.identifier.uri
http://hdl.handle.net/11336/256406  
dc.description.abstract
Objetivo: Evaluar la función del ventrículo derecho (VD) e izquierdo (VI) en la hipertensión pulmonar (HP) mediante resonancia magnética cardíaca (RMC). Material y métodos: En pacientes con (grupo HP; n = 9) y sin (grupo control; n = 9) HP se evaluó volumen telediastólico (VTD) y telesistólico (VTS) y fracción de eyección (FE) de ventrículo derecho (VD) e izquierdo (VI), área de aurícula derecha (AD) e izquierda y diámetro de arteria pulmonar (AP). Resultados: En HP, el VD presentó mayor VTD y VTS y menor FE (HP 52 ± 5% vs. control 64 ± 2%; p < 0,05). Solo en HP se observó movimiento anormal del tabique interventricular y realce tardío en los puntos de inserción del VD en VI. En HP aumentó el área de AD y el diámetro de AP. En VD, solo en HP, la FE se correlacionó negativamente con VTD (Pearson r: –0,8290; p < 0,01) y VTS (Pearson r: –0,7869; p < 0,05). Conclusiones: La evaluación de pacientes con HP mediante RMC demuestra alteraciones fisiológicas y anatómicas de las cavidades derechas con disminución de la FE del VD que también afecta la interrelación VD/VI. Se recalca la importancia de una evaluación temprana y secuencial del VD con RMC para valorar la mejor estrategia terapéutica para cada caso en particular.  
dc.description.abstract
Objective: To evaluate the function of the right ventricle (RV) and left ventricle (LV) in pulmonary hypertension (PH) through cardiac magnetic resonance imaging (CMR). Material and method: In patients with (PH group; n = 9) and without PH (control group; n = 9), end-diastolic volume (EDV) and end-systolic volume (ESV) and ejection fraction (EF) of right (RV) and left (LV) ventricle, area of the right (RA) and left (LA) atrium and diameter of the pulmonary artery (PA) were evaluated. Results: In PH, the RV increased EDV and ESV and decreased EF (PH: 52 ± 5% vs. control: 64 ± 2%; p < 0.05). Abnormal movement of the interventricular septum and late enhancement in the insertion points of the RV in the LV were only observed in HP. HP increased the area of RA and the diameter of PA. In LV, only in HP, EF was negatively correlated with EDV (Pearson r: –0.8290; p < 0.01) and ESV (Pearson r: –0.7869; p < 0.05). Conclusions: CMR evaluation of patients with PH demonstrates physiological and anatomical alterations of the right cavities with decreased EF in RV that also affects the RV/LV interrelationship. The importance of an early and sequential evaluation of the RV with CMR is emphasized to assess the best therapeutic strategy for each particular case.  
dc.format
application/pdf  
dc.language.iso
spa  
dc.publisher
Sociedad Argentina de Radiología  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/  
dc.subject
Hipertensión Pulmonar  
dc.subject
Resonancia Magnética Cardíaca  
dc.subject
ventrículo derecho  
dc.subject.classification
Sistemas Cardíaco y Cardiovascular  
dc.subject.classification
Medicina Clínica  
dc.subject.classification
CIENCIAS MÉDICAS Y DE LA SALUD  
dc.title
Evaluación de la función ventricular en la Hipertensión Pulmonar por Resonancia Magnética Cardíaca  
dc.title
Evaluation of ventricular function in pulmonary hypertension by cardiac magnetic resonance  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2024-04-19T12:16:10Z  
dc.journal.volume
87  
dc.journal.number
1  
dc.journal.pagination
3-10  
dc.journal.pais
Argentina  
dc.journal.ciudad
Buenos Aires  
dc.description.fil
Fil: Carrizo, Álvaro D.. No especifíca;  
dc.description.fil
Fil: Lobo Marquez, Lilia L.. No especifíca;  
dc.description.fil
Fil: Socolsky, Gustavo. No especifíca;  
dc.description.fil
Fil: Hautecur, Tadeo G.. No especifíca;  
dc.description.fil
Fil: Orellana, Sergio E.. No especifíca;  
dc.description.fil
Fil: Joo Turoni, Claudio Martín. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; Argentina  
dc.journal.title
Revista Argentina de Radiología  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.scielo.org.ar/scielo.php?script=sci_arttext&pid=S1852-99922023000100003