Mostrar el registro sencillo del ítem
dc.contributor.author
Wolansky, Marcelo Javier

dc.date.available
2024-12-09T15:21:48Z
dc.date.issued
2023-02
dc.identifier.citation
Wolansky, Marcelo Javier; Análisis de un protocolo basado en la norma USEPA 1.213 para la evaluación regulatoria de la eficacia de las cebaderas en el control seguro de roedores pequeños; Asociación Española de Toxicología; Revista de Toxicología; 40; 1; 2-2023; 15-22
dc.identifier.issn
0212-7113
dc.identifier.uri
http://hdl.handle.net/11336/249865
dc.description.abstract
Varios rodenticidas modernos son formulados con compuestos anticoagulantes super-warfarínicos. Debido a su alta toxicidad en humanos, los cebos suelen ser formulados con otros ingredientes destinados a generar respuestas de rechazo en el caso de ingestión accidental o intento de suicidio; aun así, las unidades hospitalarias reportan anualmente numerosos casos de intoxicaciones con rodenticidas. Se han desarrollado cebaderas con el propósito de brindar al usuario alta eficacia y seguridad extendida. Dado que en muchos países existe experiencia limitada para la evaluación regulatoria de cebos combinados con cebaderas, en este trabajo se presenta un protocolo adaptado a partir de la guía USEPA 1.213/1990, el cual se propone para verificar la aptitud de las cebaderas para controlar roedores en ambientes hogareños, ocupacionales y otros espacios urbanos. Se incluye una discusión de aspectos técnicos que se espera que sean de ayuda para los asesores de las agencias regulatorias intervinientes al interpretar los resultados en términos de eficacia y seguridad. El sistema cebadera-cebo examinado mostró alta eficacia (≥90% letalidad). La inspección, carga y recarga de producto fresco se realizó en forma simple, rápida y segura; sólo excepcionalmente se observó dispersión del cebo fuera de la cebadera. Sin embargo, debe tenerse en cuenta que el sistema que solicita un registro ante la autoridad regulatoria debe ser adecuado a la especie que se busca controlar, considerando las diferencias de peso corporal entre ratas y ratones, entre machos y hembras, y entre animales jóvenes y adultos, lo cual determina la facilidad de ingreso al interior del dispositivo (cebadera) donde se coloca el cebo contenido en su embalaje unitario original.
dc.description.abstract
Several modern rodenticides are formulated with anticoagulant superwarfarin compounds. Due to their high toxicity in humans, these baits are usually formulated with other ingredients intended to generate rejection responses in the case of accidental ingestion or suicide attempt. However, hospital units report numerous cases of poisoning with rodenticides every year. Box-like bait stations have been developed to provide the user with high efficacy and extended safety. Given that in many countries there is limited experience for the regulatory consideration of bait stations, this work presents a protocol adapted from the USEPA-1.213/1990 guideline, proposed to verify the aptitude of these devices to control wild rodents in home, work, and other urban spaces. The work includes a discussion of technical issues that are expected to be helpful to advisors of the regulatory agencies involved in interpreting the results in terms of efficacy and safety. The bait-station system examined showed high efficacy in young adult rats. The inspection, loading and reloading of fresh product were carried out in a simple, fast and safe way; bait dispersal outside the station was only rarely observed. However, it must be taken into account that the system that require a registration by the regulatory authority must be appropriate to the species sought to be controlled. This is important due to differences in body weight between rats and mice, between males and females, and between young and aged animals, which determines the ease of entry into the station where the bait contained in its original unitary packaging is placed.
dc.format
application/pdf
dc.language.iso
spa
dc.publisher
Asociación Española de Toxicología
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
RODENTICIDA
dc.subject
EFICACIA
dc.subject
NORMA USEPA 1213
dc.subject
EVALUACION REGULATORIA
dc.subject
CEBADERA
dc.subject
SEGURIDAD
dc.subject.classification
Salud Pública y Medioambiental

dc.subject.classification
Ciencias de la Salud

dc.subject.classification
CIENCIAS MÉDICAS Y DE LA SALUD

dc.subject.classification
Toxicología

dc.subject.classification
Medicina Básica

dc.subject.classification
CIENCIAS MÉDICAS Y DE LA SALUD

dc.title
Análisis de un protocolo basado en la norma USEPA 1.213 para la evaluación regulatoria de la eficacia de las cebaderas en el control seguro de roedores pequeños
dc.title
Analysis of a protocol based on the USEPA 1.213 standard for the regulatory evaluation of the efficacy of the bait station system in the safe control of small rodent
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2024-04-19T12:12:32Z
dc.journal.volume
40
dc.journal.number
1
dc.journal.pagination
15-22
dc.journal.pais
España

dc.description.fil
Fil: Wolansky, Marcelo Javier. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Química Biológica de la Facultad de Ciencias Exactas y Naturales. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de Química Biológica de la Facultad de Ciencias Exactas y Naturales; Argentina. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Departamento de Química Biológica; Argentina
dc.journal.title
Revista de Toxicología
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://dialnet.unirioja.es/servlet/articulo?codigo=9007481
Archivos asociados