Artículo
Evaluation and validation of a PrintrLab-based LAMP assay to identify Trypanosoma cruzi in newborns in Bolivia: A proof-of-concept study
Rojas Panozo, Lizeth; Rivera Nina, Silvia; Wehrendt, Diana Patricia
; Casellas, Aina; Pinto, Lilian; Mendez, Susana; Kuo, Chi Wei; Lozano, Daniel F.; Ortiz, Lourdes; Pinazo, Maria Jesus; Picado, Albert; Sanz, Sergi; Abril, Marcelo; Gascon, Joaquim; Wong, Season; Schijman, Alejandro Gabriel
; Torrico, Faustino; Alonso Padilla, Julio
Fecha de publicación:
09/2024
Editorial:
Elsevier
Revista:
The Lancet Microbe
ISSN:
2666-5247
Idioma:
Inglés
Tipo de recurso:
Artículo publicado
Clasificación temática:
Resumen
Vertical transmission of Trypanosoma cruzi represents approximately 20% of new Chagas disease cases. Early detection and treatment for women of childbearing age and newborns is a public health priority, but the lack of a simple and reliable diagnostic test remains a major barrier. We aimed to evaluate the performance of a point-of-care loop-mediated isothermal amplification (LAMP) assay for the detection of T cruzi. In this proof-of-concept study, we coupled a low-cost 3D printer repurposed for sample preparation and amplification (PrintrLab) to the Eiken T cruzi-LAMP prototype to detect vertically transmitted T cruzi, which we compared with standardised PCR and with the gold-standard algorithm (microscopy at birth and 2 months and serological study several months later). We screened pregnant women from two hospitals in the Bolivian Gran Chaco province, and those who were seropositive for T cruzi were offered the opportunity for their newborns to be enrolled in the study. Newborns were tested by microscopy, LAMP, and PCR at birth and 2 months, and by serology at 8 months.Between April 23 and Nov 17, 2018, 986 mothers were screened, among whom 276 were seropositive for T cruzi (28·0% prevalence, 95% CI 25·6-31·2). In total, 224 infants born to 221 seropositive mothers completed 8 months of follow-up. Congenital transmission was detected in nine of the 224 newborns (4·0% prevalence, 1·9-7·5) by direct microscopy observation, and 14 more cases were diagnosed serologically (6·3%, 3·6-10·3), accounting for an overall vertical transmission rate of 10·3% (6·6-15·0; 23 of 224). All microscopy-positive newborns were positive by PrintrLab-LAMP and by PCR, while these techniques respectively detected four and five extra positive cases among the remaining 215 microscopy-negative newborns. The PrintrLab-LAMP yielded a higher sensitivity than microscopy-based analysis. Considering the simpler use and expected lower cost of LAMP compared with PCR, our findings encourage its evaluation in a larger study over a wider geographical area.
Palabras clave:
CHAGAS DISEASE
,
VERTICAL TRANSMISSION
,
REPURPOSED 3D PRINTER
,
LAMP
Archivos asociados
Licencia
Identificadores
Colecciones
Articulos(INGEBI)
Articulos de INST.DE INVEST.EN ING.GENETICA Y BIOL.MOLECULAR "DR. HECTOR N TORRES"
Articulos de INST.DE INVEST.EN ING.GENETICA Y BIOL.MOLECULAR "DR. HECTOR N TORRES"
Citación
Rojas Panozo, Lizeth; Rivera Nina, Silvia; Wehrendt, Diana Patricia; Casellas, Aina; Pinto, Lilian; et al.; Evaluation and validation of a PrintrLab-based LAMP assay to identify Trypanosoma cruzi in newborns in Bolivia: A proof-of-concept study; Elsevier; The Lancet Microbe; 5; 9; 9-2024; 1-8
Compartir
Altmétricas