Mostrar el registro sencillo del ítem

dc.contributor.author
Bia, Daniel  
dc.contributor.author
Zócalo, Yanina  
dc.contributor.author
Armentano, Ricardo Luis  
dc.contributor.author
Laza, Sebastián  
dc.contributor.author
Pérez, Héctor  
dc.contributor.author
Craiem, Damian  
dc.contributor.author
Saldías, María  
dc.contributor.author
Álvarez, Inés  
dc.date.available
2024-10-03T10:52:20Z  
dc.date.issued
2009-04  
dc.identifier.citation
Bia, Daniel; Zócalo, Yanina; Armentano, Ricardo Luis; Laza, Sebastián; Pérez, Héctor; et al.; Non-Invasive biomechanical evaluation of implanted human cryopreserved arterial homografts: Comparison with pre-implanted cryografts and arteries from human donors and recipients; Springer; Annals Of Biomedical Engineering; 37; 7; 4-2009; 1273-1286  
dc.identifier.issn
0090-6964  
dc.identifier.uri
http://hdl.handle.net/11336/245389  
dc.description.abstract
Native vessels-grafts biomechanical mismatch (BM) is related to graft failure. The BM could be reduced using human cryopreserved/defrosted arteries (cryografts), but post-thaw cryografts´ recovery could be associated with an impaired biomechanical behavior. In vitro, we demonstrated that our cryopreservation methods do not affect arteries´ biomechanics, but only post-implant studies would allow determining the cryografts´ biomechanical performance. AIM: To characterize the biomechanical properties of implanted cryografts, and to compare them with cryografts pre-implant, recipients´ native arteries, and arteries from subjects with characteristics similar to those of the recipients and multiorgan donors (MOD) whose arteries were cryopreserved. METHODS: Native femoral arteries anastomosed to cryografts, implanted cryografts, and arteries from subjects, recipient-like and MOD-like, were studied. In vitro (pre-implant cryografts) and in vivo non-invasive studies were performed. Arterial pressure, diameter, and wall thickness were obtained to quantify local and regional biomechanical parameters, and to evaluate the arterial remodeling. CONCLUSION: Implanted cryografts were remodeled, with an increased wall thickness, wall-to-lumen ratio, and wall cross-sectional area. The proximal-distal gradual transition in stiffness remained unchanged. Implanted cryografts were stiffer than MOD-like arteries, but more compliant than recipients´ arteries. The cryografts-native arteries biomechanical differences were lesser than those described for venous grafts or expanded polytetrafluoroethylene.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Springer  
dc.rights
info:eu-repo/semantics/restrictedAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
Arterial remodeling  
dc.subject
Biomechanical mismatch  
dc.subject
B-mode echography  
dc.subject
Cryopreserved homografts  
dc.subject.classification
Ingeniería Eléctrica y Electrónica  
dc.subject.classification
Ingeniería Eléctrica, Ingeniería Electrónica e Ingeniería de la Información  
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS  
dc.title
Non-Invasive biomechanical evaluation of implanted human cryopreserved arterial homografts: Comparison with pre-implanted cryografts and arteries from human donors and recipients  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2024-09-23T13:47:50Z  
dc.journal.volume
37  
dc.journal.number
7  
dc.journal.pagination
1273-1286  
dc.journal.pais
Alemania  
dc.journal.ciudad
Berlin  
dc.description.fil
Fil: Bia, Daniel. Universidad de la República; Uruguay  
dc.description.fil
Fil: Zócalo, Yanina. Universidad de la República; Uruguay  
dc.description.fil
Fil: Armentano, Ricardo Luis. Universidad Favaloro; Argentina  
dc.description.fil
Fil: Laza, Sebastián. Universidad de la República; Uruguay  
dc.description.fil
Fil: Pérez, Héctor. Universidad de la República; Uruguay  
dc.description.fil
Fil: Craiem, Damian. Universidad Favaloro; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina  
dc.description.fil
Fil: Saldías, María. Universidad de la República; Uruguay  
dc.description.fil
Fil: Álvarez, Inés. Universidad de la República; Uruguay  
dc.journal.title
Annals Of Biomedical Engineering  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://link.springer.com/article/10.1007/s10439-009-9693-2  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1007/s10439-009-9693-2