Bia, Daniel; Zócalo, Yanina; Armentano, Ricardo Luis; Laza, Sebastián; Pérez, Héctor; et al.; Non-Invasive biomechanical evaluation of implanted human cryopreserved arterial homografts: Comparison with pre-implanted cryografts and arteries from human donors and recipients; Springer; Annals Of Biomedical Engineering; 37; 7; 4-2009; 1273-1286
dc.identifier.issn
0090-6964
dc.identifier.uri
http://hdl.handle.net/11336/245389
dc.description.abstract
Native vessels-grafts biomechanical mismatch (BM) is related to graft failure. The BM could be reduced using human cryopreserved/defrosted arteries (cryografts), but post-thaw cryografts´ recovery could be associated with an impaired biomechanical behavior. In vitro, we demonstrated that our cryopreservation methods do not affect arteries´ biomechanics, but only post-implant studies would allow determining the cryografts´ biomechanical performance. AIM: To characterize the biomechanical properties of implanted cryografts, and to compare them with cryografts pre-implant, recipients´ native arteries, and arteries from subjects with characteristics similar to those of the recipients and multiorgan donors (MOD) whose arteries were cryopreserved. METHODS: Native femoral arteries anastomosed to cryografts, implanted cryografts, and arteries from subjects, recipient-like and MOD-like, were studied. In vitro (pre-implant cryografts) and in vivo non-invasive studies were performed. Arterial pressure, diameter, and wall thickness were obtained to quantify local and regional biomechanical parameters, and to evaluate the arterial remodeling. CONCLUSION: Implanted cryografts were remodeled, with an increased wall thickness, wall-to-lumen ratio, and wall cross-sectional area. The proximal-distal gradual transition in stiffness remained unchanged. Implanted cryografts were stiffer than MOD-like arteries, but more compliant than recipients´ arteries. The cryografts-native arteries biomechanical differences were lesser than those described for venous grafts or expanded polytetrafluoroethylene.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Springer
dc.rights
info:eu-repo/semantics/restrictedAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
Arterial remodeling
dc.subject
Biomechanical mismatch
dc.subject
B-mode echography
dc.subject
Cryopreserved homografts
dc.subject.classification
Ingeniería Eléctrica y Electrónica
dc.subject.classification
Ingeniería Eléctrica, Ingeniería Electrónica e Ingeniería de la Información
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS
dc.title
Non-Invasive biomechanical evaluation of implanted human cryopreserved arterial homografts: Comparison with pre-implanted cryografts and arteries from human donors and recipients
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2024-09-23T13:47:50Z
dc.journal.volume
37
dc.journal.number
7
dc.journal.pagination
1273-1286
dc.journal.pais
Alemania
dc.journal.ciudad
Berlin
dc.description.fil
Fil: Bia, Daniel. Universidad de la República; Uruguay
dc.description.fil
Fil: Zócalo, Yanina. Universidad de la República; Uruguay
dc.description.fil
Fil: Armentano, Ricardo Luis. Universidad Favaloro; Argentina
dc.description.fil
Fil: Laza, Sebastián. Universidad de la República; Uruguay
dc.description.fil
Fil: Pérez, Héctor. Universidad de la República; Uruguay
dc.description.fil
Fil: Craiem, Damian. Universidad Favaloro; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
dc.description.fil
Fil: Saldías, María. Universidad de la República; Uruguay
dc.description.fil
Fil: Álvarez, Inés. Universidad de la República; Uruguay
dc.journal.title
Annals Of Biomedical Engineering
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://link.springer.com/article/10.1007/s10439-009-9693-2
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1007/s10439-009-9693-2
Archivos asociados